Indoor Unit
3.3

Floor / Ceiling Suspended Dual Type

3.3.1 FLXS25/35/50/60BAVMB
Connectors and
PCB (1): Control PCB
Other Parts
1) S6
2) S7
3) S21
4) S24
5) S26
6) S32
7) S37
8) JA
9) SW2
10) LED A
PCB (2): Power Supply PCB
1) S36
2) H1, H2, H3
3) H4, H5, H6
4) V1
5) FU1
PCB (3): Display PCB
1) S25
2) LED1 (H1P)
3) LED2 (H2P)
4) LED3 (H3P)
PCB (4): Signal Receiver PCB
1) S27
2) S31 (RTH)
3) SW1 (S1W)
46
Connector for swing motor (horizontal swing)
Connector for AC fan motor
Connector for centralized control (HA)
Connector for display PCB
Connector for signal receiver PCB
Connector for indoor heat exchanger thermistor
Connector for power supply PCB
Address setting jumper
Refer to page 154 for detail.
JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function
Refer to page 157 for detail.
Select switch for installation (ceiling or floor)
Refer to page 157 for detail.
LED for service monitor (green)
Connector for control PCB
Connector for terminal board
Connector for AC fan motor
Varistor
Fuse (3.15 A, 250 V)
Connector for control PCB
LED for operation (green)
LED for timer (yellow)
LED for HOME LEAVE operation (red)
Connector for control PCB
Room temperature thermistor
Forced operation ON/OFF button
Printed Circuit Board Connector Wiring Diagram
SiBE18-821_C