Outdoor Unit
Step
Before working, make
sure that the refrigerant
gas is empty in the circuit.
Be sure to apply nitrogen
replacement when
heating up the brazed
part.
6
Disconnect the brazed
part of the electronic
expansion valve.
7
Disconnect the brazed
part of the high
pressure switch.
448
Procedure
Brazed part
Electronic
expansion valve
Be careful not to get yourself
(main)
burnt with the pipes and other
parts that are heated by the
gas brazing machine.
If the refrigerant gas leaks
during work, ventilate the
room. (If the refrigerant gas is
Electronic
expansion valve
exposed to flames, toxic gas
(subcooling)
may be generated.)
From the viewpoint of global
environment protection, do
not discharge the refrigerant
gas in the atmosphere. Make
(R12981)
sure to collect all the
refrigerant gas.
Cautions for restoration
1. Restore the piping by non-
oxidation brazing.
2. It is required to prevent the
carbonization of the oil inside
the four way valve and the
deterioration of the gaskets
affected by heat. (Keep
below 120°C.) For the sake
of this, wrap the four way
valve with wet cloth and
provide water so that the
cloth does not dry.
High pressure switch
In case of difficulty with gas
(R13062)
brazing machine
1. Disconnect the brazed part
where is easy to disconnect
and restore.
2. Cut pipes on the main unit
with a tube cutter in order to
make it easy to disconnect.
SiBE18-821_C
Points
Warning
Warning
Caution
Removal Procedure