SiBE18-821_C
G-Series, 20-50 Class
G-Series, 60/71 Class
< Floor Standing Type>
1) Remove the front grille.
2) Lift the sensor PCB fixing plate and remove the front shield plate.
3) Disconnect the connectors [S1] [S41] [S42].
4) Remove the electric box (1 screw).
5) Pull out the indoor heat exchanger thermistor.
6) Remove the shield plate (8 tabs).
7) Cut the address jumper JA on the indoor unit PCB.
8) Cut the address jumper J4 in the remote controller.
Test Operation and Field Settings
ADDRESS
JA
JA
ADDRESS
EXIST
1
CUT
2
JB
JA
JC
(Refer to "Wireless remote controller".)
4) Remove the screw.
6) Shield plate
F-Series
ADDRESS
EXIST
CUT
(R12216)
(R11735)
5) Indoor heat exchanger
thermistor
3) Connector [S42]
3) Connector [S41]
3) Connector [S1]
JA Address
JC
JA
EXIST
1
JB
CUT
2
2) Sensor
2) Front shield plate
Field Settings
(R2872)
PCB fixing
plate
(R11692)
155