Operation/procedure
Set the OC cover at 20 degrees detection and press the [START] key.
The detection output level of each sensor is displayed in real time.
Original cover state
OCSW
Open: Highlighted display
Close: Normal display
1 to 5
PD sensor detection level (Hexadecimal display)
The value in [ ] shows the threshold value of 20 degree detection
adjustment. (Hexadecimal display)
For AB series, 1 to 5 is displayed, for inch series, 1 to 4.
During execution, [EXECUTING] is highlighted.
43
43-1
Purpose
Setting
Function
Used to set the fusing temperature.
(Purpose)
Section
Fixing (Fusing)
Item
Operation
Operation/procedure
1. Touch the item to be set.
2. Enter the set value with the 10-key.
Item
Content
Ready
Ready
1
Temp Main
temperature Main
(145)
(145mm/s)
Ready
Ready
2
Temp Sub
temperature Sub
(145)
(145mm/s)
Ready
Ready
3
Temp Main
temperature Main
(122)
(122mm/s)
Ready
Ready
4
Temp Sub
temperature Sub
(122)
(122mm/s)
WarmUp
Warmup target
5
Target Main
temperature Main
(145)
(145mm/s)
WarmUp
Warmup target
6
Target Sub
temperature Sub
(145)
(145mm/s)
WarmUp
Warmup target
7
Target Main
temperature Main
(122)
(122mm/s)
WarmUp
Warmup target
8
Target Sub
temperature Sub
(122)
(122mm/s)
WarmUp
Warmup
Temp Main
complete
9
(145)
temperature Main
(145mm/s)
WarmUp
Warmup
Temp Sub
complete
10
(145)
temperature Sub
(145mm/s)
WarmUp
Warmup
Temp Main
complete
11
(122)
temperature Main
(122mm/s)
Default
Setting
(North
range
America
(Europe)
/Others)
150 -
185
190
220
150 -
180
185
220
150 -
175
180
220
150 -
170
175
220
150 -
180
190
220
150 -
180
190
220
150 -
175
220
150 -
170
220
0 - 40
10
0 - 40
15
0 - 40
10
MX-M260/M310/M260N/M310N SIMULATION 6 - 24
Item
Content
WarmUp
Warmup
Temp Sub
complete
12
(122)
temperature Sub
(122mm/s)
600dpi
600dpi Main
13
Main (145)
(145mm/s)
600dpi Sub
600dpi Sub
14
(145)
(145mm/s)
POST
Postcard Main
15
CARD
(145mm/s)
Main (145)
POST
Postcard Sub
16
CARD Sub
(145mm/s)
(145)
CARDBOA
Thick paper Main
17
RD Main
(145mm/s)
(145)
CARDBOA
Thick paper Sub
18
RD Sub
(145mm/s)
(145)
600dpi
600dpi Main
19
Main (122)
(122mm/s)
600dpi Sub
600dpi Sub
20
(122)
(122mm/s)
CARDBOA
Postcard Main
21
RD Main
(122mm/s)
(122)
POST
Postcard Sub
22
CARD Sub
(122mm/s)
(122)
POST
Thick paper Main
23
CARD
(122mm/s)
(122mm/s)
CARDBOA
Thick paper Sub
24
RD Sub
(122mm/s)
(122)
43-10
Purpose
Setting
Function
Used to set the paper feed cycle timing when printing
(Purpose)
postcards.
Section
Paper feed
Item
Operation
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Setting range
1-99
Default
50
44
44-1
Purpose
Setting
Function
Used to make various setups in each mode of process
(Purpose)
control.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Default
Setting
(North
range
America
(Europe)
/Others)
0 - 40
15
150 -
190
195
220
150 -
190
195
220
150 -
200
220
150 -
200
220
150 -
200
220
150 -
200
220
150 -
175
185
220
150 -
175
185
220
150 -
190
220
150 -
190
220
150 -
190
220
150 -
190
220

Hide quick links: