Simulation Code List - Sharp MX-M260 Service Manual

Digital multifunctional system
Hide thumbs Also See for MX-M260:
Table of Contents

Advertisement

2. Simulation code list

Code
Main
Sub
Used to check the operation of the scanner unit
1
and its control circuit.
1
Used to check the operation of sensor and detector
2
in the scanning (read) section and the related circuit.
Used to check the operation of the RSPF unit and
1
the related circuit.
Used to check the operation of sensors and detectors
2
2
in the RSPF unit and the related circuit.
Used to check the operation of the loads in the
3
RSPF unit and the control circuits.
Used to check the operation of sensor and detector
2
in the finisher and the related circuit.
Used to check the operation of the load in the
3
finisher and the control circuit.
10
Used to make each adjustment of the finisher.
3
Used to check the shifter operation.
Reciprocating operations are continuously
11
performed or the home position is checked.
(The shifter is shifted to the home position or
moved in one way by the specified steps.)
Used to check the operation of sensor and detector
2
in the option tray and the related circuit.
4
Used to check the operation of the load in the
3
option tray and the control circuit.
Used to check the operation of the display (LED),
1
LCD in the operation panel, and control circuit.
Used to check the operation of the heater lamp and
5
2
the control circuit.
Used to check the operation of the copy lamp and
3
the control circuit.
Used to check the operation of the loads (clutches
1
and solenoids) in the paper transport system and
the control circuit.
6
Used to check the operation of each fan motor and
2
its control circuit.
1
Used to set the aging operation conditions.
7
6
Used to set the cycle of intermittent aging.
8
Used to set the display of the warm-up time.
Used to check and adjust the operation of the
1
developing bias voltage in each copy mode and the
control circuit.
Used to check and adjust the operation of the main
2
charger grid voltage in each copy mode and the
control circuit.
Used to check and adjust the operation of the
10
developing bias voltage in each printer mode and
the control circuit.
8
Used to check and adjust the operation of the main
11
charger grid voltage in each printer mode and the
control circuit.
Used to check and adjust the operation of the
13
developing bias voltage in FAX mode and the
control circuit.
Used to check and adjust the operation of the main
14
charger grid voltage in FAX mode and the control
circuit.
Used to check and adjust the operation of the load
1
(motor) in the duplex section and the control circuit.
4
Duplex motor RPM setting
9
Used to adjust the timing of switching from normal
5
rotation to reverse rotation or from reverse rotation
to normal rotation of the duplex motor.
Used to check the operation of the toner motor and
10
0
its control circuit.
Function
MX-M260/M310/M260N/M310N SIMULATION 6 - 3
Code
Main
Sub
Used to cancel excluding the self-diag U2/PF
14
0
troubles.
16
0
Used to cancel the self-diag U2 trouble.
17
0
Used to cancel the self diag "PF" trouble.
21
1
Used to set the maintenance cycle.
1
Used to check the counter value of each section.
Used to check the total numbers of misfeed and
troubles. (When the number of misfeed is
2
considerably great, it is judged as necessary for
repair. The misfeed rate is obtained by dividing this
count value with the total counter value.)
Used to check the misfeed positions and the
number of misfeed at each position.
3
(When the number of misfeed is considerably
great, it can be judged as necessary for repair.)
4
Used to check the total trouble (self diag) history.
Used to check the ROM version of each unit
5
(section).
Used to print each key operator setting, the
6
account information, and the machine adjustment
22
values.
7
Used to display of the administrator password.
8
Used to display the original, staple counter.
Used to check the number of use of each paper
9
feed section. (the number of prints)
10
Used to check the system configuration.
Used to display the FAX send/receive counter
11
(FAX reception and print counter).
Used to check the misfeed positions and the
number of misfeed at each position.
12
(When the number of misfeed is considerably
great, it can be judged as necessary for repair.)
13
Used to display the CRUM type.
Used to display the scanner counter in the network
19
scanner mode.
Used to clear the misfeed counter, the misfeed
history, the trouble counter, and the trouble history.
1
(The counters are cleared after completion of
maintenance.)
Used to clear the number of use (the number of
2
prints) of each paper feed section.
Used to clear the number usage data of the stapler,
3
RSPF, and scanning.
4
Used to reset the maintenance counter.
Used to reset the developer counter.
5
(The developer counter of the DV unit which is
24
installed is reset.)
6
Used to clear the copy counter.
Used to clear the OPC drum (membrane decrease)
7
correction counter. (This simulation is executed
when the OPC drum is replaced.)
Used to clear the printer counter and other
9
counters.
10
FAX counter data clear
Used to clear the scanner counter in the network
15
scanner mode.
Used to check the operation of the main drive
(excluding the scanner section) and to check the
1
operation of the toner concentration sensor.
(The toner concentration sensor output can be
25
monitored.)
Used to make the initial setting of toner
2
concentration when replacing developer.
Function