General
Power requirements
Sony AC Power Adaptor AC-DA300
(supplied) connected at the DC IN 12 V
jack : 120V AC, 60Hz (US model)
Power consumption
20 W
5 °C to 35 °C (41°F to 95°F)
Operating temperature
Operating humidity
30% to 85%
Approx. 280 × 80 × 290 mm
Dimensions
× 3
1
(11
/
8
(w/h/d, including projecting parts and
controls)
Mass
Approx. 2.5 kg (5 lb. 8 oz)
Supplied accessories
AC power adaptor AC-DA300
Remote commander RMT-DA300 (1)
Size AA (R6) batteries (2)
Design and specifications are subject to change without notice.
CAUTION
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Flexible Circuit Board Repairing
TE
• Keep the temperature of soldering iron around 270˚C
L 13942296513
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by
the manufacturer.
Discard used batteries according to the manufacturer's instructions.
www
.
http://www.xiaoyu163.com
× 11
1
1
/
/
inches)
4
2
x
ao
y
i
— 2 —
http://www.xiaoyu163.com
8
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2.
A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
Q Q
To Exposed Metal
3
6 7
1 3
Parts on Set
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH
MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE ! SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
u163
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
.
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
2 9
9 4
2 8
1 5
0 5
8
2 9
9 4
AC
voltmeter
1.5k Ω
(0.75V)
Earth Ground
À LA SÉCURITÉ!
m
co
9 9
2 8
9 9