Viessmann VITOCAL 300-G Installation And Service Instructions Manual page 167

Compact heat pump with electric drive single and two-stage, type bw/bws, ww/wws
Table of Contents

Advertisement

Repairs
(cont.)
Temperature sensors type Pt 500
860
780
700
620
540
460
-20
20
60
Temperature in °C
Checking the fuse
For fuse locations, see from page 220:
■ Fuse F1 is located on the cross con-
nect PCB.
■ Fuse F3 is located on the main PCB.
Fuse F1 and F3:
■ 6.3 A (slow), 250 V~
■ Max. power loss ≤ 2.5 W
Appliance too noisy
Possible causes:
■ Transport brackets not removed or not
secured to the base carrier: See
page 68.
■ Control unit door not tightly sealed:
See page 116.
100
140 180
Capturing element "Pt 500"
■ Flow temperature sensor, system
(F13)
■ Buffer temperature sensor (F4)
■ Cylinder temperature sensor (F6)
■ Flow/return temperature sensor, sec-
ondary circuit (F8/F9)
■ All sensors inside the heat pump
■ Boiler temperature sensor, external
heat source
Danger
Contact with 'live' components
can lead to severe injury from
electric current.
Before working on the equip-
ment, always ensure that the
power circuit is also at zero
volt.
Removing the fuse does not
switch the power circuit to zero
volt.
■ Base sheets not fitted: See page 116
step 5.
■ Clearance between the base sheet
and floor is too great.
Troubleshooting