Further details regarding the individual steps
Filling and venting the solar circuit
Danger
Overheated collector areas and
overheated heat transfer medium
can cause burns/scalding and
equipment damage.
When working on the collector
and the solar circuit with heat
transfer medium, protect the col-
lector areas against solar irradia-
tion.
1. Check the pre-charge pressure of the
diaphragm expansion vessel.
Checking expansion vessels and the primary circuit/heating cir-
cuit pressure
Observe design information.
Vitocal technical guide
Commissioning assistant
The commissioning assistant guides you
automatically through all the menus
where settings have to be made.
!
Please note
Incorrect operation at "Coding
level 1" can result in damage to
the appliance and heating sys-
tem.
Always observe the installation
and service instructions; failure to
observe these will void your war-
ranty rights.
Commissioning, inspection, maintenance
(cont.)
!
2.
Please note
To prevent equipment dam-
age, only fill the solar circuit
with Tyfocor LS.
3. Vent the solar circuit.
Minimum system pressure: 1.7 bar
Permiss. operating pressure: 6 bar
Note
■ The scan "Start commissioning
assistant?" only appears during ini-
tial commissioning.
■ The configuration, parameter settings
and function check can also be carried
out without the commissioning assis-
tant (see page 171, separate menu
structure and operating instructions).
■ When the unit is first commissioned,
the display is in German: