Chapter 8 Basic Setting
Table 18 Remote CPE Configuration (continued)
LABEL
Enable
Relay
Port
Isolation
Wan Common
Qos
Auto
Gateway
Default
Gateway
Virtual Port Select Enable to turn Virtual Port on in the CPE device or select Disable to turn it off.
Remote
Function
SSH /
SNMP /
Web / TFTP
/ Telnet
AP
ManagemE
nable
Apply to CO
Cancel
Commit to CPE Click this to transfer all settings configured above to the CPE device. The CPE will then restart
CFM
Action
Destination
MAC
Loopback
Count
ma name
md level
md name
mep id
vid
94
DESCRIPTION
Select this to have the CPE assign IP addresses to LAN hosts. When you select Enable, fill in
the starting/ending IP addresses for the DHCP IP assignment range in the Start IP and End
IP fields and the subnet mask in the MASK field.
Select this to have the CPE forward DHCP requests to another DHCP server. When you select
Relay, fill in the DHCP server's IP address in the IP field.
Specify a LAN port (1~4) on the CPE device. Click an index number link to display the LAN
settings on the connected CPE.
Select Enable to stop communications between the specified port and other Ethernet LAN
ports to prevent interference from other ports. Select Disable to turn it off.
Select Enable to turn QoS on in the CPE device or select Disable to turn it off.
Select Enable to have the CPE's ISP assign the gateway IP address or select Disable to turn
it off.
Fill in the gateway IP address provided by the CPE's ISP.
Use this section to configure the remote management settings for the CPE device.
Select OFF to disallow any access to the device through a specific protocol.
Select ALL On to allow access to the device from both CPE device's LAN and WAN network
through a specific protocol.
Select LAN On to allow access to the device from the CPE device's LAN network through a
specific protocol.
Select WAN On to allow access to the device from the CPE device's WAN network through a
specific protocol.
Select Enable to turn on the wireless LAN on the CPE device or select Disable to turn it off.
Click this to save the settings configured above in the Switch's temporary memory.
Note: All CPE settings stored on the Switch will be cleared once the Switch restarts.
Click this to reset the settings above to their previous configuration.
itself automatically to apply the changes.
Configure Connectivity Fault Management for the CPE device.
Enter 0 to store the CFM settings in the switch. Enter 3 to perform the CFM loopback test on
the CPE device. Enter 5 to load the CFM default settings on the CPE device.
Enter the target device's MAC address to which the CPE performs a CFM loopback test.
Sets the number of CFM loopback messages (1~999) the CPE device sends in a loopback test.
Specify the maintenance association's (MA) name on the CPE device.
Specify the maintenance domain's (MD) level on the CPE device.
Specify the MD's name on the CPE device.
Specify the maintenance end point's (MEP) ID on the CPE device.
Specify the VLAN ID under this MA on the CPE device.