ZyXEL Communications VES1724-56 User Manual page 324

24-port temperature-hardened vdsl2 box dslam
Hide thumbs Also See for VES1724-56:
Table of Contents

Advertisement

Chapter 38 Access Control
Table 150 SNMP Interface Traps (continued)
OPTION
OBJECT LABEL
DdmiRxPowerAlarmEventOn
DdmiVoltageAlarmEventOn
DdmiTxBiasAlarmEventOn
DdmiTemperatureWarnEven
tOn
DdmiTxPowerWarnEventOn
DdmiRxPowerWarnEventOn
DdmiVoltageWarnEventOn
DdmiTxBiasWarnEventOn
DdmiTemperatureAlarmEve
ntCleared
DdmiTxPowerAlarmEventCle
ared
DdmiRxPowerAlarmEventCl
eared
DdmiVoltageAlarmEventCle
ared
DdmiTxBiasAlarmEventClea
red
DdmiTemperatureWarnEven
tCleared
DdmiTxPowerWarnEventCle
ared
324
OBJECT ID
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
DESCRIPTION
This trap is sent when a transceiver's
received optical power goes over the
"high alarm" threshold.
This trap is sent when a transceiver's
voltage goes over the "high alarm"
threshold.
This trap is sent when a transceiver's
laser bias current goes over the "high
alarm" threshold.
This trap is sent when a transceiver's
temperature goes over the "high
warning" threshold.
This trap is sent when a transceiver's
transmitted optical power goes over the
"high warning" threshold.
This trap is sent when a transceiver's
received optical power goes over the
"high warning" threshold.
This trap is sent when a transceiver's
voltage goes over the "high warning"
threshold.
This trap is sent when a transceiver's
laser bias current goes over the "high
warning" threshold.
This trap is sent when a transceiver's
temperature falls down below the the
high alarm threshold and is back to the
normal range.
This trap is sent when a transceiver's
transmitted optical power falls down
below the the high alarm threshold and
is back to the normal range.
This trap is sent when a transceiver's
received optical power falls down below
the the high alarm threshold and is back
to the normal range.
This trap is sent when a transceiver's
voltage falls down below the the high
alarm threshold and is back to the
normal range.
This trap is sent when a transceiver's
laser bias current falls down below the
the high alarm threshold and is back to
the normal range.
This trap is sent when a transceiver's
temperature falls down below the the
high warning threshold and is back to
the normal range.
This trap is sent when a transceiver's
transmitted optical power falls down
below the the high warning threshold
and is back to the normal range.
VES1724-56 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ves1724-56b2

Table of Contents