The following table describes the labels in this screen.
Table 132 Advanced Application > SFP Threshold Setup
LABEL
Port Index
Port
Vendor
Part Number
Serial Number
Revision
transceiver
User Input
Enable
Apply
Cancel
Type
Current
High Alarm
Threshold
High Warning
Threshold
Low Warning
Threshold
Low Alarm
Threshold
Apply
Cancel
VES1724-56 User's Guide
DESCRIPTION
Select the port number of an SFP slot on the Switch for which you want to configure the
thresholds.
This field displays the port number of the selected SFP slot.
This field displays the vendor of the transceiver installed in the slot.
This field displays the part number of the installed transceiver.
This field displays the part number of the transceiver.
This field displays the version of the transceiver.
This field displays the name of the transceiver.
Select this option to turn on the thresholds and configure the thresholds if you want to
receive SNMP traps when the SFP slots are operating abnormally.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Click Cancel to begin configuring this screen afresh.
This is the type of device operating parameters.
This shows the current value of each parameter measured for the installed transceiver.
Specify the first upper limit for each parameter. The Switch sends an alarm trap when one of
the parameter values goes over this value.
Specify the second upper limit for each parameter. The Switch sends a warning trap when
one of the parameter values goes over this value. This value should be smaller than the High
Alarm Threshold and greater than the Low Warning Threshold.
Specify the first lower limit for each parameter. The Switch sends a warning trap when one
of the parameter values falls below this value. This value should be smaller than the High
Warning Threshold and greater than the Low Alarm Threshold.
Specify the second lower limit for each parameter. The Switch sends an alarm trap when one
of the parameter values falls below this value. This value should be smaller than the Low
Warning Threshold.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Click Cancel to begin configuring this screen afresh.
Chapter 33 SFP Threshold
293