Chapter 8 Basic Setting
Table 15 Basic Setting > IP Setup (continued)
LABEL
In-Band Management IP Address
DHCP Client
Static IP Address
IP Address
IP Subnet Mask
Default Gateway
VID
Out-of-band Management IP Address
IP Address
Subnet Mask
Default Gateway
Apply
Cancel
In-band IP Addresses
You can create up to 64 IPv4 addresses, which are used to access and manage the Switch from the ports
belonging to the pre-defined VLAN(s). You must configure a VLAN first.
IP Address
IP Subnet Mask
VID
Default Gateway
Add
Cancel
Index
IP Address
IP Subnet Mask
VID
84
DESCRIPTION
Select this option if you have a DHCP server that can assign the Switch an IP address,
subnet mask, a default gateway IP address and a domain name server IP address
automatically.
Select this option if you don't have a DHCP server or if you wish to assign static IP
address information to the Switch. You need to fill in the following fields when you select
this option.
Enter the IP address of your Switch in dotted decimal notation for example 192.168.1.1.
Enter the IP subnet mask of your Switch in dotted decimal notation for example
255.255.255.0.
Enter the IP address of the default outgoing gateway in dotted decimal notation, for
example 192.168.1.254.
Enter the VLAN identification number associated with the Switch IP address. This is the
VLAN ID of the CPU and is used for management only. The default is "1". All ports, by
default, are fixed members of this "management VLAN" in order to manage the device
from any port. If a port is not a member of this VLAN, then users on that port cannot
access the device. To access the Switch make sure the port that you are connected to is
a member of Management VLAN.
Enter the IP address of your Switch in dotted decimal notation for example 192.168.0.1.
If you change this IP address, make sure the computer connected to this management
port is in the same subnet before accessing the Switch.
Enter the IP subnet mask of your Switch in dotted decimal notation for example
255.255.255.0.
Enter the IP address of the default outgoing gateway in dotted decimal notation, for
example 192.168.0.254.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top
navigation panel to save your changes to the non-volatile memory when you are done
configuring.
Click Cancel to begin configuring the fields again.
Enter the IP address for managing the Switch by the members of the VLAN specified in
the VID field below.
Enter the IP subnet mask in dotted decimal notation.
Type the VLAN group identification number.
Enter the IP address of the default outgoing gateway in dotted decimal notation.
Click Add to insert the entry to the summary table below and save your changes to the
Switch's run-time memory. The Switch loses these changes if it is turned off or loses
power, so use the Save link on the top navigation panel to save your changes to the
non-volatile memory when you are done configuring.
Click Cancel to reset the fields to your previous configuration.
This field displays the index number of the rule. Click an index number to edit the rule.
This field displays the IP address.
This field displays the subnet mask.
This field displays the ID number of the VLAN group.