ZyXEL Communications VES1724-56 User Manual page 370

24-port temperature-hardened vdsl2 box dslam
Hide thumbs Also See for VES1724-56:
Table of Contents

Advertisement

Chapter 48 Product Specifications
Table 174 Hardware Specifications
Security
Physical and Environmental Specifications
Dimensions
Weight
Power Specification
Power Consumption
LEDs
Operating Environment
Storage Environment
Ground Wire Gauge
Power Wire Gauge
Fan
370
Static MAC address filtering
Static MAC address forwarding
MAC Freeze
IEEE 802.1x port-based authentication
Limiting number of dynamic MAC addresses per port
SSH v1/v2
SSL
Multiple RADIUS servers
Multiple TACACS+ servers
802.1X VLAN and bandwidth assignment.
MAC authentication
Standard 19" rack mountable
439.8 mm (W) x 300 mm (L) x 66 mm (H)
5.5 kg
AC (dual input ranges):
100 VAC to 120 VAC, 50/60 Hz, 1.7 A Max.
220 VAC to 240 VAC, 50/60 Hz, 0.75 A Max.
DC:
-36 VDC to -72 VDC, 4 A Max.
Note: There is no tolerance for the DC input voltage.
63 Watt Max.
Per switch: PWR, SYS, ALM
Per Fast Ethernet RJ-45 port: 10 M, 100 M, 1000 M
Per mini-GBIC slot: LNK, ACT
Per Management port: 10 M, 100 M
Temperature: 0º C ~ 65º C (32º F ~ 149º F)
Humidity: 10 ~ 90% (non-condensing)
Temperature: -40º C ~ 70º C (-40º F ~ 158º F)
Humidity: 0 ~ 90% (non-condensing)
18 AWG or larger
18 AWG or larger
Supports fan speed detection, temperature detection, voltage detection,
fan speed control, and hot-swappable fan module features.
VES1724-56 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ves1724-56b2

Table of Contents