ZyXEL Communications VES1724-56 User Manual page 323

24-port temperature-hardened vdsl2 box dslam
Hide thumbs Also See for VES1724-56:
Table of Contents

Advertisement

Table 149 SNMP System Traps (continued)
OPTION
OBJECT LABEL
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
loopguard
LoopguardEventOn
externalarm
ExternalAlarmEventOn
ExternalAlarmEventClear
Table 150 SNMP Interface Traps
OPTION
OBJECT LABEL
linkup
linkUp
LinkDownEventClear
linkdown
linkDown
LinkDownEventOn
autonegotiatio
AutonegotiationFailedEvent
n
On
AutonegotiationFailedEvent
Clear
SFP
DdmiTemperatureAlarmEve
ntOn
DdmiTxPowerAlarmEventOn
VES1724-56 User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.0.1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.6.3.1.1.5.3
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
1
1.3.6.1.4.1.890.1.5.12.46.45.2.
2
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
Chapter 38 Access Control
DESCRIPTION
This trap is sent when the temperature
goes above or below the normal operating
range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the voltage returns
to the normal operating range.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets
by an administrator through a
management interface.
This trap is sent when the Switch reboots
by an administrator through a
management interface.
This trap is sent when loopguard shuts
down a port.
This trap is sent when the external alarm
is received.
This trap is sent when the external alarm
stops sending an alert.
DESCRIPTION
This trap is sent when the Ethernet link
is up.
This trap is sent when the Ethernet link
is up.
This trap is sent when the Ethernet link
is down.
This trap is sent when the Ethernet link
is down.
This trap is sent when an Ethernet
interface fails to auto-negotiate with the
peer Ethernet interface.
This trap is sent when an Ethernet
interface auto-negotiates with the peer
Ethernet interface.
This trap is sent when a transceiver's
temperature goes over the "high alarm"
threshold.
This trap is sent when a transceiver's
transmitted optical power goes over the
"high alarm" threshold.
323