4) Pull the drive belt (front) [1] in the direction of the arrow to move he con-
tact sensor [2] to the center.
5) Remove the contact sensor [3] together with the mount.
- Screw[4], 2 pcs
6) Remove the contact sensor HP sensor.
[4]

4.4.7 Original Size Sensor

4.4.7.1 Removing the Original Sensor (Vertical Scan
Direction)
1) Open the copyboard cover (or ADF).
2) Remove the copyboard glass.
3) detach the cover [1].
- Screw [2], 1 pcs
[1]
[1]
[2]
[3]
F-4-45
[2]
F-4-46
4) Disconnect the flexible cable [1], and then detach the cover [2].
- Screw [3], 1 pcs
5) Pull the drive belt (front) [4] in the direction of the arrow to move the con-
tact sensor [5] to the left.
[5]
6) Disconnect the connector [1], and then remove the harness from the edge
saddle/clamp [2].
7) remove the original sensor (vertical scan direction) [3] together with the
mount.
- Screw [4], 3 pcs
0017-8502
8) Remove the original sensor (vertical scan direction) [1].
- connector [2], 2 pcs
[2]
4.4.7.2 Removing the Original Sensor (Horizontal Scan
Direction)
1) Open the copyboard cover (or ADF).
2) Remove the copyboard glass.
[2]
[3]
[4]
F-4-47
[2]
[1]
[3]
F-4-48
[1]
F-4-49
Chapter 4
[1]
[4]
0017-8505
4-19