Comtech EF Data SLM-7650 Installation And Operation Manual page 155

Comtech ef data satellite modem installation and operation manual
Table of Contents

Advertisement

SLM-7650 Satellite Modem
Remote Control Specifications
Parameter 33:
Parameter 34:
Parameter 35:
Parameter 36:
Parameter 37:
Parameter 38:
Parameter 39:
Parameter 40:
Parameter 41:
Parameter 42:
Parameter 43:
Demod RS Codeword (ref. "DRSC_" command).
P33 = n, where: 'n' is '0' = RS(225,205,10) depth 8,
Interface Coding Format Receive (ref. "ICFR_"
command).
P34 = n, where 'n' is '0' (AMI), '1' (B6ZS), '2' (B8ZS), or '3'
(HDB3).
Interface Service Channel Level RX1 (ref. "ISCL_RX1_"
command).
P35 = snn.n, where 'snn.n' is -6.0 to +8.0 in steps of 2 dB.
Interface Service Channel Level RX2 (ref. "ISCL_RX2_"
command).
P36 = snn.n, where 'snn.n' is -6.0 to +8.0 in steps of 2 dB.
Insert Data Format (ref. "IDF_" command).
P37 = n, where 'n' is '0' (T1), '1' (T1ESF), '2' (E1CCS), or '3'
(E1CAS).
Bulk Insert Channel Assignment (ref. "BICA_"
command).
P38 = dd;cc_dd;cc_dd;cc_dd;cc..., as defined by the
'BICA_' command.
IDR Backward Alarm RX1 (ref. "BW_RX1_" command).
P39 = n, where 'n' is '0' (OFF) or '1' (ON).
IDR Backward Alarm RX2 (ref. "BW_RX2_" command).
P40 = n, where 'n' is '0' (OFF) or '1' (ON).
IDR Backward Alarm RX3 (ref. "BW_RX3_" command).
P41 = n, where 'n' is '0' (OFF) or '1' (ON).
IDR Backward Alarm RX4 (ref. "BW_RX4_" command).
P42 = n, where 'n' is '0' (OFF) or '1' (ON).
IDR Receive ESC Type (ref. "RET_" command).
P43 = 0, where 'n' is '0' (2x32Kbit/s Audio) or '1' (64Kbit/s
Data).
A–13
Revision 4
MN/SLM7650.IOM
'1' = RS(225,205,10) depth 4,
'2' = RS(219,201,9) depth 8,
'3' = RS(219,201,9) depth 4,
'4' = RS(194,178,8) depth 4,
'5' = RS(126,112,7) depth 4