Displaying ''Totals'' (Displayed Cycles And Hours Totals) Onto Message Display; Table 9. Displayed Error Conditions - Cornelius FCB POST-MIX DISPENSER Installation & Service Manual

Two or four-flavor w/hot-gas defrost and v3+features
Table of Contents

Advertisement

MESSAGE
DISPLAYED
Motor 1
Motor 2
Motor 1
Motor 2
REFRIG
** Maximum Run Time on compressor
SYRUP 1
SYRUP 2
CO
OUT
2
H
O
2
SENSOR 1
SENSOR 2
SENSOR 3
* The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss
has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and
carbonator will stop.
** 25 minutes on Standard System, 30 minutes on Remote System.
DISPLAYING ''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE
DISPLAY
(see Table 4 and Table 8).
''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on message display as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTION ONTO MESSAGE DISPLAY and bring up the word
''CLOCK'' on message display.
2. Repeatedly press and release ''CANCEL DEFROST'' (ADVANCE) switch to advance through main menu
until ''TOTALS'' menu appears on message display. Press ''DEFROST'' (SELECT) switch to lock
''TOTALS'' menu in place. The word ''COMP HRS'' will appear on message display.
3. Press and hold ''DEFROST'' (SELECT) switch. Compressor run hours will appear on message display.
4. Press ''CANCEL DEFROST'' (ADVANCE) switch to advance and bring up ''COMP CYC'' on message
display.
5. Press and hold ''DEFROST'' (SELECT) switch. Compressor cycles x 100 will appear on message display.
6. Use CANCEL DEFROST (ADVANCE) switch to advance through remaining ''TOTALS'' (DISPLAYED
CYCLES AND HOURS TOTAL MENU) (see Table 8). Press ''DEFROST'' (SELECT) switch to obtain
message display readings of the individual menu selections.
7. Press ''ERROR RESET'' switch two times to exit from MENU SELECTIONS.
2813
ERROR
Low Current, < 109,
Sensed on motor one
Low Current, < 109,
Sensed on motor two
High Current, > 255,
Sensed on motor one
High Current, > 255,
Sensed on motor two
Syrup Out Side One
Syrup Out Side Two
CO
Out
2
H
O Out
2
Temp Sensor Inlet One
Temp Sensor Inlet Two
Temp Sensor Outlet

TABLE 9. DISPLAYED ERROR CONDITIONS

ITEMS AFFECTED BY ERROR
BEATER
BEATER
MOTOR 1
MOTOR 2
OFF
OFF
OFF
OFF
OFF
OFF
50
REFRIG 1
REFRIG 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
*OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
*OFF
OFF
OFF
OFF

Hide quick links: