CONNECTING SOFT DRINK TANKS CO
ASSEMBLY
(see applicable Figure 2 or 3)
1. Connect soft drink tanks CO
Figure 2 or 3.
2. Install gas quick disconnects on ends of soft drink tanks CO
TANKS AT THIS TIME.

PREPARING UNIT SYRUP INLET LINES FOR CONNECTION TO SOFT DRINK TANKS

(see applicable Figure 2 or 3 )
1. Route Unit syrup inlet lines, labeled No. 1 and No. 2 (two-flavor Units) or No.1, No. 2, No.11, and No. 22
(four-flavor Units) out through hole provided in the Unit base to the soft drink tanks location.
2. Install liquid disconnects on ends of Unit syrup inlet lines. DO NOT CONNECT SYRUP LINES TO TANKS
AT THIS TIME.

CONNECTING CITY PLAIN WATER Source LINE (S) TO UNIT

Note: All of the Units require connection to a City plain water source line with a minimum water
pressure of 12 psig to be connected to the Unit plain water inlet line which provides plain water to the
Unit post-mix system. The Units equipped with water-cooled refrigeration systems also require a City
plain water source line to be connected to the refrigeration cooling coil(s) plain water inlet lines.
Proceed as follows to connect a City plain water source line(s) to the Unit.
Connecting City Plain Water Source Line to Unit Post-Mix System.
(see applicable Figure 2 or 3 )
NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in the City
plain water source line (see applicable Figure 2 or 3 ) that provides plain water to the Dispenser
post-mix system. A Cornelius Water Filter (P/N 313860000) and Quick Disconnect Set (P/N 313867000)
are recommended.
1. Before connecting the City plain water source line to the Unit that provides plain water to the post-mix
system, open shutoff valve in City plain water source line for a period of time to flush out any metal
shavings.
2. Route Unit plain water inlet line out through hole in bottom of Unit base.
NOTE: Carbonator plain water inlet adjustable water pressure regulator (see Figure 12) is factory
adjusted to 45 psi and should not be readjusted.
3. Connect Unit plain water inlet line to the City plain water source line (12 psi minimum pressure). Seal
connection with TAPERED GASKET, BLACK (item 4). DO NOT OPEN THE CITY PLAIN WATER
SOURCE LINE SHUTOFF VALVE AT THIS TIME.
Connecting City Plain Water Source Line(s) to Unit With Water-Cooled Refrigeration System.
(See Figure 17)
Note: The water-cooled Two-Flavor FCB Post-Mix Dispenser has one water-cooled refrigeration system
which requires connection of a City plain water source line to its refrigeration cooling coil plain water
inlet line. The water-cooled Four-Flavor FCB Post-Mix Dispenser has two refrigeration systems and
requires a City plain water source line to be connected to its two refrigeration cooling coils plain water
inlet lines. THE CITY PLAIN WATER SOURCE LINE MUST INCLUDE A WATER SHUTOFF VALVE.
Proceed as follows to connect the City plain water source line to the Dispensers refrigeration cooling
coil(s) plain water inlet line(s).
2813
LINES TO PRIMARY CO
2
lines to primary CO
regulator manifold assembly as shown in applicable
2
2
14
REGULATOR
2
lines. DO NOT CONNECT CO
2
LINES TO
2