Replenishing Syrup Supply; Figure 11. Liquid Check Valve Assembly - Cornelius FCB POST-MIX DISPENSER Installation & Service Manual

Two or four-flavor w/hot-gas defrost and v3+features
Table of Contents

Advertisement

index no
part
no
1
317965000
2
312196000
3
312419000
4
312415000
5
312418000
6
317963000
Install new ball seat each servicing.
7. Assemble check valves together. DO NOT OVERTIGHTEN.
8. Make sure white tapered gasket is in place inside female end of double liquid check valve assembly, then
install check valve assembly on elbow in water pump outlet port.
9. Connect carbonator tank water line to double liquid check valve assembly outlet. DO NOT
OVERTIGHTEN.
10. Open CO
cylinder and water inlet supply lines shutoff valves. Check for water leaks and tighten any loose
2
connections.
11. Install Unit back panel by reversing removal procedure.
12. Connect electrical power to Unit.
13. Press both ''AUTO BLEND 1'' and ''AUTO BLEND 2'' switches.
14. Press both ''AUTO 1'' and ''AUTO 2'' switches to start freeze cylinders beaters and refrigeration system.

REPLENISHING SYRUP SUPPLY

NOTE: Sugar–free diet syrup cannot be used with this Unit.
Although syrup replenishing can be done anytime, syrup supply must be replenished when either ''SYRUP 1'' or
''SYRUP 2'' fault messages are displayed on message display indicating either No. 1 or No. 2 syrup system soft
drink tank is empty.
NOTE: The following instructions are applicable only when replenishing syrup supply. Refer to SYRUP
FLAVOR CHANGE when changing syrup flavors.
1. Press applicable ''OFF 1'' or ''OFF 2'' switch to stop applicable freeze cylinder beater and refrigeration
system.
IMPORTANT: The following CO
replacement or filling soft drink tank in place must be performed in order as follows:
2813
6
Retainer
Spring
Ball
Washer, .300 I.D.
Quad Ring
Body

FIGURE 11. LIQUID CHECK VALVE ASSEMBLY

and liquid disconnect and connecting procedure for soft drink tank
2
1
3
2
4
5
name
56

Hide quick links:

Advertisement