Control Panel Display Messages - Cornelius FCB POST-MIX DISPENSER Installation & Service Manual

Two or four-flavor w/hot-gas defrost and v3+features
Table of Contents

Advertisement

''AUTO 1'' and ''AUTO 2'' Control Switches.
''AUTO 1'' and ''AUTO 2'' control switches, located on control panel (see Figure 6), are touch-type switches and
require only pressing to activate. These switches are used to operate freeze cylinders beaters and refrigeration
system after cylinders have been filled with product. Freeze cylinders beaters and refrigeration system may be
stopped by pressing ''OFF 1'' or ''OFF 2'' switches.
''OFF 1'' and ''OFF 2'' Control Switches.
''OFF 1'' and ''OFF 2'' control switches, located on control panel (see Figure 6), are touch-type switches and
require only pressing to activate. These switches are used to stop freeze cylinders beaters and refrigeration
system.
''ERROR RESET'' Control Switch.
''ERROR RESET'' control switch, located on control panel (see Figure 6), is a touch-type switch and requires
only pressing to activate. ''ERROR RESET'' switch is used to restore normal operation after error within Unit
(indicated by ''ERROR 1'' or ''ERROR 2'' on message display) has been corrected.
''SECURITY SWITCH.''
The Unit is equipped with a hidden ''SECURITY SWITCH'' located between ''FILL 1'' switch and ''ERROR
RESET'' switch on control panel (see Figure 6). Pressing in and holding ''SECURITY SWITCH'' for 3 seconds
deactivates control switches to prevent tampering with the Unit is normal operation. To reactivate control
switches, press in and hold ''SECURITY SWITCH'' for 3 seconds.

CONTROL PANEL DISPLAY MESSAGES

(see Figure 6)
''FILL 1'' and ''FILL 2'' Fault Messages.
''FILL 1'' and ''FILL 2'' fault messages will appear on message display only when ''FILL 1'' and ''FILL 2'' control
switches have been pressed and syrup systems sold-out floats have been filled with product. ''FILL 1'' and ''FILL
2'' fault messages will continue to be displayed until ''AUTO BLEND 1'' or ''AUTO BLEND 2'' control switches
have been pressed to fill product blender tanks with product.
''ERROR 1'' and ''ERROR 2'' Fault Messages.
''ERROR 1'' and ''ERROR 2'' fault messages will appear on message display only if error within Unit has
developed interrupting normal operation. Error will have to be located and corrected, then press ''ERROR
RESET'' to restore normal operation. ''ERROR 1'' or ''ERROR 2'' fault message will disappear from display.
''OFF 1'' and ''OFF 2'' Fault Messages.
''OFF 1'' and ''OFF 2'' fault messages will appear on message display when either freeze cylinder beater is not
operating.
''H
O OUT'' Fault Message.
2
The Unit plain water inlet system contains a water pressure switch. If the plain water source to the Unit is
disrupted or a water pressure drop occurs. The ''H
Unit will continue to operate for 1-1/2 minutes after ''H
pressure has not been restored or water pressure improved after 1-1/2 minutes, Unit operation will shut down.
After plain water source has been restored or water pressure has improved, Unit will resume operation and
''H
O OUT'' fault message will disappear from message display.
2
2813
O OUT'' fault message will appear on the message display if
2
O OUT'' fault message has appeared and if water