DISPLAYING ''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE
DISPLAY
''TOTALS'' (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on the message display as
instructed in the SERVICE AND MAINTENANCE section.

PROGRAMMING FREEZE CYLINDERS BEATER "MOTORS" INTO UNIT ELECTRONICS

Note in 6 "MOTOR SELECT" the number of freeze cylinders beater motors Manufacturer's that are listed. Your
Unit was manufactured and equipped with motors from one of these Manufacturer's. A replacement freeze
cylinder beater motor is also manufactured by one of these Manufacturer's listed. NOTE THE
MANUFACTURER'S NAME ON THE MOTOR(S). THE BEATER MOTOR(S) MANUFACTURER'S NAME(S)
MUST BE PROGRAMMED INTO THE UNIT WHICH WILL MATCH THE MOTOR(S) TO THE UNIT
ELECTRONICS as instructed in SERVICE AND MAINTENANCE section.

PROGRAMMING PROPER REFRIGERANT TYPE INTO UNIT ELECTRONICS

The Dispenser electronics must be programmed for the proper refrigeration pulse rate according to the type of
refrigerant gas that has been installed in the refrigeration system. Note Dispenser serial plate for the type of
refrigerant gas that has been installed, then proceed to SERVICE AND MAINTENANCE section for
programming instructions.

DISPLAYED ERROR CONDITIONS

Displayed error conditions, associated errors, and items affected by the errors are found in Table 9
DISPLAYED ERROR CONDITIONS.
WATER STRAINER SCREEN AND DOUBLE LIQUID CHECK VALVE
MAINTENANCE
(see Figures 11 and 12)
WARNING: The carbonator water pump water strainer screen and double liquid check valve
must be inspected and serviced after any disruptions (plumbing work, earthquake, etc.) to
the water supply system, and at least once a year under normal circumstances. Water
pump with no screen or defective screen in strainer would allow foreign particles to foul the
double liquid check valve. CO
hazard in the system.
Service water strainer screen and double liquid check valve as instructed in the SERVICE AND
MAINTENANCE section.
CLEANING CO
GAS CHECK VALVES
2
(see applicable Figure 2 or 3 and 13 )
The CO
gas check valves must be inspected and serviced at least once a year under normal conditions, and
2
after any servicing or disruption of the CO
2813
gas could then back flow into water system and create a health
2
system as instructed in the SERVICE AND MAINTENANCE section.