Adjustment And Programming Main Menu Selections Into Unit; Programming Main Menu Selection Onto Message Display; Setting Clock (Time Of Day); Table 4. Main Menu Selections - Cornelius FCB POST-MIX DISPENSER Installation & Service Manual

Two or four-flavor w/hot-gas defrost and v3+features
Table of Contents

Advertisement

ANY TIME THE NO. 4 ''BEATER MOTOR CURRENT READOUT'' SWITCH ON DIP SWITCH ASSEMBLY IS
PLACED IN ''ON'' POSITION, THE BEATER MOTOR CURRENT READINGS MUST BE READJUSTED TO
A150B150 ± 2 AS INSTRUCTED, THEN SWITCH MUST BE PLACED BACK IN THE ''OFF'' POSITION.

ADJUSTMENT AND PROGRAMMING MAIN MENU SELECTIONS INTO UNIT

NOTE: The Unit control panel switches are as shown in Figure 9.
The following instructions outline adjustments and programming main menu selections, components
''DIAGNOSE'' (DIAGNOSTIC MODE), and ''TOTALS" (DISPLAYED CYCLES AND HOURS TOTALS) into the
Unit.
MENU SELECTIONS
"CLOCK" (TIME OF DAY)
"DEFROST" (AUTOMATIC)
"SLEEP" (SLEEP TIME)
"WAKE UP" (WAKE UP TIME)
"VIS SET" (PRODUCT VISCOSITY SETTING)
"VIS READ" (ACTUAL VISCOSITY READOUT)
"SENSORS (TEMPERATURES READOUT)
"VOLTAGE" (DISPLAYED VOLTAGE READOUT)
"DIAGNOSE" (DIAGNOSTIC MODE)
"TOTALS"
"MOTORS" (BEATER MOTOR MANUFACTURER)
"REF TYPE" (REFRIGERANT TYPE)
NOTE: the "CLOCK" (TIME OF DAY) must be programmed into the Unit before "DEFROST"
(AUTOMATIC) "SLEEP" (SLEEP TIME), and "WAKE UP" (WAKE UP TIME) will function.
NOTE: Plain water, CO
2
OUT'', ''SYRUP 1'', and ''SYRUP 2'' fault messages on message display before adjustments and
programming procedures can be performed on the Unit.

PROGRAMMING MAIN MENU SELECTION ONTO MESSAGE DISPLAY

The MAIN MENU SELECTIONS (see Table 4) may be brought up on the message display as follows:
1. Press ''AUTO 1'', ''WASH 1'', and ''BLEND 1'' control switches (see Figure 9) at the same time and hold
them pressed for a minimum of 1/2 second to bring up MAIN MENU SELECTIONS on message display.
The word ''CLOCK'' will appear on display. You are now in the MAIN MENU SELECTIONS as shown in
Table 4 To advance through the MENU SELECTIONS, repeatedly press the ''CANCEL DEFROST''
(ADVANCE) switch. Once you reach the desired selection, press the ''DEFROST'' (SELECT) switch to lock
in on the selection.
NOTE: To exit MENU SELECTION and return to MAIN MENU SELECTIONS, press ''ERROR RESET''
(RESET) switch. Press ''ERROR RESET (RESET) switch again to exit from MAIN MENU SELECTIONS.

SETTING CLOCK (TIME OF DAY)

NOTE: The CLOCK (TIME OF DAY) must be programmed into Unit before ''DEFROST'' (AUTOMATIC),
''SLEEP'' (SLEEP TIME), and ''WAKE UP'' (WAKE UP TIME) can be programmed into the Unit. Program
''CLOCK'' (TIME OF DAY) into Unit as follows:
2813
see note below

TABLE 4. MAIN MENU SELECTIONS

and syrup supplies to Unit must be satisfied to turn off ''H
MESSAGE DISPLAY
(EXAMPLE READOUTS)
C
_
1
3
D
1
S
1
2
W
_
0
1
2
_
1
6
_
7
5
*
V
R
M
See Programming Components Diagnose into
Unit.
See Table 7 and programming "TOTALS"
(DISPLAYED CYCLES AND HOURS TOTALS)
into unit.
See Table 6.
See PROGRAMMING PROPER
REFRIGERANT TYPE INTO UNIT
ELECTRONICS
42
2
-
0
0
0
-
0
0
-
3
0
A
7
-
1
5
_
_
_
1
_
_
_
1
7
5
*
7
S
*
2
3
O OUT'', ''CO
2
2
A
A
_
A
0
1
5
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents