4. Press "DEFROST" (SELECT) switch to lock in on the selection. This programs the proper refrigeration
pulse rate into the Dispenser electronics.
5. Press "ERROR RESET" switch two times to exit from "MAIN MENU SELECTIONS".

DISPLAYED ERROR CONDITIONS

Displayed error conditions, associated errors, and items affected by the errors are found in 9 DISPLAYED
ERROR CONDITIONS.

CLEANING AND SANITIZING

DAILY CLEANING OF UNIT

Daily, or more often if necessary, wash all external surfaces of Unit with a mild soap solution. Rinse with clean
water, then wipe dry with a clean soft cloth. DO NOT USE ABRASIVE CLEANERS. Remove and wash drip tray
in mild soap solution; rinse with clean water, then install drip tray on Unit.

SANITIZING SYRUP SYSTEMS

NOTE: The Unit should be sanitized every 90 days following Sanitizer Manufacturers recommendation.
Use Chlor-Tergent (Oakite Products, Inc.) or equivalent sanitizer.
The Unit should be sanitized every 90 days and before and after storage periods following parent company
requirements and sanitizer manufacturer's recommendations. One or both syrup systems may be sanitized at
one time for routine 90 days sanitizing requirements. The following sanitizing instructions use No. 1 syrup
system as an example. No. 2 syrup systems sanitizing instructions are identical to No. 1 syrup system with
exception of using applicable system switches. Proceed as follows:
1. Press ''OFF 2'' switch to stop beater motor and refrigeration in No. 2 freeze cylinder which is not to be
defrosted. ''OFF 2'' fault message will appear on message display.
2. Press ''DEFROST'' switch to start defrost cycle on No. 1 freeze cylinder. ''DEFROST 1'' message will
appear on message display as long as defrost cycle is in progress.
3. Immediately press ''AUTO 2'' control switch to restart beater in No. 2 freeze cylinder. Refrigeration in No. 2
cylinder will not be operating.
4. Remove right-hand side panel as instructed for access to No. 2 product blender tank product shutoff valve.
5. Close No. 2 product blender tank product shutoff valve to prevent product bleeding back into No. 1 product
blender tank during sanitizing procedure.
IMPORTANT: The following CO
soft drink tank replacement or filling soft drink tank in place must be performed in order as follows:
6. To disconnect soft drink tank from Unit syrup system.
A.
Disconnect liquid disconnect soft drink tank. NOTE: Disconnecting liquid quick disconnect from
soft drink tank first prevents syrup from backflowing through Unit syrup flow regulator which
may alter regulator adjustments.
B.
Second, disconnect CO
2813
and liquid disconnects disconnecting and connecting procedure for
2
quick disconnect from soft drink tank.
2
52