Safety Precautions; Shipping And Storage; Co2 (Carbon Dioxide) Warning; Power Cord - Cornelius Bubble Installation, Operation & Service Manual

Post-mix beverage dispenser
Table of Contents

Advertisement

!
WARNING
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING
AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. FAILURE TO COMPLY COULD RESULT IN
SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE.
S
P
AFETY
RECAUTIONS
This unit has been specifically designed to provide protection against personal injury. To ensure continued protection
observe the following:
!
WARNING:
Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify all of
the power is off to the unit before any work is performed.
Failure to disconnect the power could result in serious injury, death or equipment damage.
!
CAUTION:
Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in injury or
equipment damage.
S
A
S
HIPPING
ND
!
CAUTION:
Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution must be drained from
the system. A freezing ambient environment will cause residual sanitizing solution or water remaining inside the unit to
freeze resulting in damage to internal components.
CO
(C
D
2
ARBON
!
DANGER:
CO
displaces oxygen. Strict attention MUST be observed in the prevention of CO
2
soft drink system. If a CO
area before attempting to repair the leak. Personnel exposed to high concentrations of CO
are followed rapidly by loss of consciousness and DEATH.
P
C
OWER
ORD
If the power cord is damaged, it must be replaced by a special cord available from the manufacturer or its service agent.
Detachable cord sets should meet the below requirements:
Cord type should be H05VV-F or stronger, with earthing conductor;
Cord section should be minimum nominal cross-sectional area of 1.0mm^2;
Plug should also be earthing type and obtain approval with above cord.
S
L
OUND
EVEL
The A-weighted sound pressure level has been determined to be below 70dBA.
U
L
NIT
OCATION
This unit is not designed for use in outdoor locations.
TORAGE
) W
IOXIDE
ARNING
gas leak is suspected, particularly in a small area, IMMEDIATELY ventilate the contaminated
2
2
gas leaks in the entire CO
2
gas experience tremors which
2
© 2019, Cornelius Inc
and
2