Glass Replacement; Gasket Replacement; Inspect The Vent System Annually; Check The Gas Flame Regularly - Vermont Castings RADVT(CS)CBSB Installation And Operating Instructions Manual

Radvt series direct vent gas heater
Table of Contents

Advertisement

Radiance
Direct Vent Gas Heater
®

Glass Replacement

Replace glass only with Vermont Castings Group approved
parts. Refer to Replacement Parts section for correct glass.
Refer to Figure 85 and previous instructions for removal of
the damaged glass frame.
Fig. 85 Remove the stove front.
ST139
Radiance
remove front
4/20/01 djt
Fig. 86 Release the latches to remove the glass frame.

Gasket Replacement

The Radiance Gas Heater uses a 'tadpole' type gasket to
seal between the glass panel and the frame. In time, this
gasket can become brittle and compressed and should be
replaced. New gasket is available from your dealer.
Shut off the gas supply and allow the stove to cool. Wear
safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel. (Figs.
85 & 86) Remove the old gasket. Use a razor blade
to separate the glass and gasket from the frame, and
to clean the glass of any remaining cement or bits of
gasket. Use a cold chisel if necessary.
2. Determine the correct length of gasket by laying it out
around the edge of the glass. Allow an extra 1 - 2" (25-
50mm). Mark the spot to be cut. Use a utility knife.
4444
3. Starting on a long edge, remove about 6" of the pro-
tective paper strip and apply the flat adhesive face of
the gasket around the outside-facing edge of the panel.
Continue around the panel, applying about 6" at a time
and being careful to not stretch the material. Do not
overlap the gasket ends. (Fig. 87)
4. Apply a thin bead of high temperature silicone rubber
sealant along the inside corner of the glass frame, all
around the perimeter. Place the flat gasketed side of the
glass panel back into the steel frame. Pinch the rounded
inside-facing gasket material to bulk it up.
5. Replace the glass frame and front panel as previously
described.
ST139a
Fig. 87 Wrap the gasket material around the outside edge of
the glass.
Have the vent system inspected annually by a qualified
technician. Shut off the main gas supply before inspecting
the system. Both the inner exhaust pipe and the outer
combustion supply pipe must be checked to confirm that
they are unblocked and in good condition.
ST141
To ensure that the stove is operating properly, check the
flames periodically to confirm they match Figure 88. The
flames will be blue during the first 15-20 minutes of oper-
ation, and will gradually turn to yellow after that.
S T141
pull glass latch
10/ 99
Do not use your stove if the flame pattern differs from that
shown here. Contact your Vermont Castings dealer or a
qualified technician for help.
Figure 88
ST179

Inspect the Vent System Annually

glass gasket detail
11/99

Check the Gas Flame Regularly

LG490
all logs
6/07
ST179
20306759

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents