3. To check, press either the ON or OFF button on the
transmitter and the receiver indicator light will blink. If
not, repeat Step 2.
4. The system is now ready to operate.
NOTE: Refer to optional 6 Hour Shutdown.
WARNING: Do not use two (2) or more remote
control systems in the same area with the same
dip switch settings, they will communicate with
each other. This may cause the appliances to
malfunction.
Dip Switch
(Default)
ON
DIP
Transmitter
Fig. 60 The switches on the transmitter and receiver must
match.
ST1089
RCSITE dip switches
20306759
ON
DIP
Receiver
ST1089
Radiance
Reset Button
The reset button can be used to reset the transmitter if
transmitter is not working properly. The reset button is lo-
cated behind the battery door cover in the lower left cor-
ner of battery compartment. Using a paper clip, press the
reset button and the transmitter will reset and initialize for
10 seconds before it can be used.
Operation
Transmitter
General
The RCSITEA Remote Control has two (2) operating
modes: Manual and Thermostatic. The control system
can be set to temperature ranges between 45°F and
90°F. The blower speed and flame height can be adjusted
in either the manual or thermostatic mode.
The transmitter will operate the remote receiver from 1
foot to a maximum of 30 feet. The distance is reduce
when batteries are low or when the
receiver is inside a metal enclosure.
Direct Vent Gas Heater
®
ON
AUTO
FAN
FLAME
OFF
AMBIENT
Fig. 61 RCSITEA
remote transmitter.
ST1090
RCSITE remote
35