Outdoor Unit
2.6

Removal of Partition Plate and Reactor

Procedure
Step
1. Remove the partition plate.
Remove the two
1
screws fixing the
partition plate.
2
Pull the partition plate
upward to remove.
144
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Partition plate
Points
(R1485)
Compressor
lead wire
(R1480)
SiBE05-311