Daikin RKS25BVMB Techical Data

Daikin RKS25BVMB Techical Data

Split sky air
Hide thumbs Also See for RKS25BVMB:

Advertisement

technical data

RKS-B
Pair Application
Split
Sky Air

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RKS25BVMB

  • Page 1: Technical Data

    technical data RKS-B Pair Application Split Sky Air...
  • Page 2 Daikin Europe N.V. is participating Daikin Europe N.V. is approved by LRQA for its Quality in the EUROVENT Certification Programme. Management System in accordance with the ISO9001 Products are as listed in the EUROVENT standard.
  • Page 3: Table Of Contents

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB TABLE OF CONTENTS RKS-B Features ................. Specifications .
  • Page 4: Features

    Outdoor units for pair application + Daikin outdoor units can be mounted easily on a roof or terrace or simply placed against an outside wall. They are fitted with a swing compressor, renowned for its low noise and high energy efficiency.
  • Page 5: Specifications

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RKS25BVMB RKS35BVMB RKS50BVMB RKS60BVMB RKS71BVMB DIMENSIONS Unit WEIGHT COLOUR Unit Ivory white SOUND LEVEL Sound pressure (1) (Cooling) High/Low 46/43 47/44 47/* 49/* 52/* Sound power (2) (Cooling)
  • Page 6: Electrical Specifications

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Specifications ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RKS25BVMB RKS35BVMB RKS50BVMB RKS60BVMB RKS71BVMB CURRENT Nominal running current cooling 3.52 5.22 6.82 9.12 10.90 Max. running current cooling Please refer to electrical data Starting current cooling 11.1...
  • Page 7: Electrical Data

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Specifications ELECTRICAL DATA RKS+FTKS25B Power supply Compressor Indoor unit Outdoor unit Hz-Volts Voltage range MAX. 50Hz 253V FTKS25BVMB RKS25BVMB 50-230 3.21 0.35 0.20 MIN. 50Hz 207V 3D040397 RKS+FTKS35B Power supply Compressor Indoor unit Outdoor unit...
  • Page 8: Electrical Data

    14+14 0.31 MIN. 50Hz 207V 3D040876 RKS+FLKS25B Power supply Compressor Indoor unit Outdoor unit Hz-Volts Voltage range MAX. 50Hz 253V FLKS25BVMB RKS25BVMB 50-230 3.17 0.35 0.34 MIN. 50Hz 207V 3D040395 RKS+FLKS35B Power supply Compressor Indoor unit Outdoor unit Hz-Volts Voltage range MAX.
  • Page 9: Electrical Data

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Specifications ELECTRICAL DATA RKS+FCQ35B RKS+FCQ50B RKS+FCQ60B * This information was not available at the time of publication. RKS+FHQ35B Power supply Compressor Indoor unit Outdoor unit Hz-Volts Voltage range MAX. 50Hz 253V FHQ35BUV1B RKS35BVMB 50-230 4.91 0.35...
  • Page 10: Capacity Tables

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FTKS25B 0.23 Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) (°C) (°C) 14.0 2.33 1.58 0.52 2.25 1.52 0.58 2.17 1.47 0.65 2.14 1.45 0.66 2.08 1.41 0.67 2.00 1.35 0.72 16.0 2.51 1.70...
  • Page 11 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FTKS71B 16.7 0.27 Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) (°C) (°C) 14.0 7.16 4.60 2.18 7.01 4.53 2.28 6.86 4.46 2.37 6.80 4.43 2.41 6.71 4.39 2.47 6.56 4.32 2.56 16.0 7.32...
  • Page 12 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FLKS25B 0.32 Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) (°C) (°C) 14.0 2.33 1.52 0.54 2.25 1.47 0.60 2.17 1.42 0.66 2.14 1.40 0.67 2.08 1.36 0.68 2.00 1.30 0.74 16.0 2.51 1.64...
  • Page 13 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FFQ35B 10.0 0.25 Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) (°C) (°C) 14.0 3.17 2.25 0.97 3.06 2.18 1.09 2.96 2.10 1.20 2.91 2.07 1.22 2.83 2.02 1.24 2.71 1.93 1.35 16.0 3.42...
  • Page 14 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FCQ35-60B Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) Outdoor (°C) (°C) 14.0 20.0 0.91 1.01 1.12 1.13 1.16 1.25 16.0 22.0 0.92 1.03 1.14 1.15 1.18 1.28 18.0 25.0 0.94 1.05 1.16 1.17...
  • Page 15 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FHQ35B 0.20 Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) (°C) (°C) 14.0 3.17 2.47 0.91 3.06 2.39 1.01 2.96 2.30 1.12 2.91 2.27 1.13 2.83 2.21 1.16 2.71 2.11 1.25 16.0 3.42 2.67...
  • Page 16 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Capacity tables RKS+FBQ35-60B Cooling capacity 230V [50Hz] Indoor Outdoor temperature (°C) Outdoor (°C) (°C) 14.0 20.0 0.91 1.01 1.12 1.13 1.16 1.25 16.0 22.0 0.92 1.03 1.14 1.15 1.18 1.28 18.0 25.0 0.94 1.05 1.16 1.17...
  • Page 17: Dimensional Drawings

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Dimensional drawings unit (mm) RKS25,35 4 x holes for anchor bolts (M8 or M10) Minimum space for air passage Wall height on air outlet side = less than 1200 Drain outlet (I.D. J 15.9 hose for connection) Name plate Terminal strip with earth Outdoor air thermistor...
  • Page 18: Operation Range

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Operation range RKS25,35,50,60,71B Notes: The graph is based on the following conditions: 1. Equivalent piping length 7.5 m 2. Level difference 3. Air flow rate high Indoor temp. (°CWB) 4D029297B • Split - Sky Air • Outdoor Units...
  • Page 19: Piping Diagrams

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Piping diagrams RKS25 Outdoor unit Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Capillary tube 1 Capillary tube 2 Muffler with filter Propeller fan Muffler with filter Muffler with filter Field piping Liquid stop valve...
  • Page 20 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Piping diagrams RKS50 Outdoor unit Heat exchanger Outdoor temperature thermistor Capillary tube 1 Muffler with Refrigerant flow filter Cooling Heat exchanger thermistor Capillary tube 2 Capillary tube 3 Propeller fan Filter Motor operated valve Muffler with filter Field piping...
  • Page 21: Wiring Diagrams

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Wiring diagrams RKS25,35 Indoor Field wiring : Protective earth Outdoor C9, C11 (outdoor) (discharge) C12∼C15 : Capacitor : Current transformer (Condenser) DB1, DB2 : Diode bridge R1T, R2T, R3T, R4T : Thermistor F1U, F2U : Fuse S10, S11, S20, S45 : Live...
  • Page 22: Sound Level

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Sound level Sound level data Cooling only Sound pressure level 230V, 50Hz Sound power level Model Cooling Measuring location (cooling) RKS25B RKS35B RKS50B RKS60B RKS71B * This information was not available at the time of publication. Sound pressure spectrum RKS25B (Cooling) RKS35B (Cooling)
  • Page 23: Sound Level Data

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Sound level Sound pressure spectrum Cooling only RKS50B RKS60B approximate approximate threshold hearing for threshold hearing continuous noise for continuous noise 4D027648B 4D040949 Octave band center frequency (Hz) Octave band center frequency (Hz) RKS71B Legend 50/60Hz, 220-240/220-230V...
  • Page 24: Accessories

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Accessories Standard accessories RKS-B Accessories supplied with the outdoor unit: Installation manual Optional accessories RKS-B RKS25BVMB RKS35BVMB RKS50BVMB RKS60BVMB RKS71BVMB Air direction adjustment grille KPW937A4 KPW945A4 • Split - Sky Air • Outdoor Units...
  • Page 25: Installation

    • Pair Application • R-410A • RKS25-35-50-60-71BVMB Installation RKS25,35B Outdoor unit installation drawings Wrap the installation pipe with the finishing tape from bottom to top Model 25 / 35 class Cooling only: 25m Max. allowable length Heat pump: 15m Max. allowable height Additional refrigerant required for refrigerant pipe exceeding 20 g/m...
  • Page 26 • Pair Application • R-410A • RKS25-35-50-60-71BVMB Installation RKS50,60,71B Outdoor unit installation drawings Wrap the installation pipe with the finishing tape from bottom to top Model 50 class 60 class 71 class Max. allowable length Max. allowable height Additional refrigerant required for refrigerant pipe exceeding 20 g/m 10 m in length.

This manual is also suitable for:

Rks50bvmbRks60bvmbRks35bvmbRks71bvmb

Table of Contents