Wiring Diagrams
2.2

Outdoor Units

RKS25 / 35BVMB
X1M
indoor
1
1
2
2
3
RED
3
L
L
BLK
N
WHT
N
TFU
102
˚C
FIELD WIRING.
NOTE
1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
X1M
: TERMINAL STRIP
C9, C11
C12~C15
: CAPACITOR
CT1
: CURRENT TRANSFORMER
DB1, DB2
: DIODE BRIDGE
FU1, FU2
: FUSE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
PCB1
: PRINTED CIRCUIT BOARD
RK25 / 35BVMB
X1M
indoor
1
1
2
2
3
RED
3
L
L
BLK
N
WHT
N
TFU
102˚C
FIELD
WIRING.
NOTE
1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
X1M
: TERMINAL STRIP
C9 , C11
C12~C15
: CAPACITOR
CT1
: CURRENT TRANSFORMER
DB1 , DB2 : DIODE BRIDGE
FU1 , FU2 : FUSE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
PCB1
: PRINTED CIRCUIT BOARD
162
PCB1
S
HL3
HL2
L1
FU2
YLW
20A
HL1
HN3
HN2
HN1
V2
BLU
S11
1
1
WHT
SA1
ORG
ORG
S10
ORG
V3
ORG
E
ORG
7
7
ORG
1
2
S45
1
YLW
S70
YLW
outdoor
M1F
MRH , MRL
MRM10 , MRM20 : MAGNETIC RELAY
N
: NEUTRAL
PCB2
: PRINTED CIRCUIT BOARD
Q1L
: OVERLOAD PROTECTOR
R1T , R2T , R3T , R4T: THERMISTOR
S10 , S11 , S20 , S45 ,
S70 , S90 , S91 ,
HL3 , HN3
: CONNECTOR
SA1
: SURGE ARRESTER
PCB1
S
HL3
HL2
FU2
L1
YLW
20A
HL1
HN3
HN2
HN1
V2
BLU
S11
1
WHT
1
SA1
ORG
ORG
S10
ORG
V3
ORG
E
ORG
7
ORG
7
1
2
S45
YLW
S70
YLW
outdoor
MRL
MRM10 , MRM20
: MAGNETIC RELAY
N
: NEUTRAL
PCB2
: PRINTED CIRCUIT BOARD
Q1L
: OVERLOAD PROTECTOR
R1T , R2T , R3T , R4T : THERMISTOR
S10 , S11 , S20 , S45 ,
S70 , S90 , S91 ,
HL3 , HN3
: CONNECTOR
SA1
: SURGE ARRESTER
L1R
PCB2
MRM20
HR3
MRM10
FU1
3.15A
V1
MRH
MRL
C9
1
3
5
8
M
~
1
R1T
R2T
( OUTDOOR )
( CONDENSER )
Z1C
IC3
TFU
TRM1
V1 , V2 , V3 : VARISTOR
Y1E
L1R
PCB2
MRM20
HR3
MRM10
FU1
3.15A
V1
MRL
C9
1
3
6
1
M
~
1
R1T
R2T
M1F
( OUTDOOR )
( CONDENSER )
Z1C
IC3
TFU
TRM1
V1 , V2 , V3 : VARISTOR
Y1E
R4T
( FIN )
HR4
S91
1
2
DB1
~
+
C12
CT1
DB2
+
~
~
-
+
-
IC3
C13
~
-
+
C11
-
6
1
6
OL2
S90
S20
6
X30A
M
R3T
Y1E
( DISCHARGE )
Q1L
: FERRITE CORE
: TRIAC
: THERMAL FUSE
: TRANSISTOR MODULE
: ELECTRONIC EXPANSION VALVE COIL
: PROTECTIVE EARTH
HR4
1
2
DB1
~
+
CT1
DB2
~
~
-
+
IC3
~
-
C11
6
1
6
OL2
S90
S20
6
X30A
M
R3T
Y1E
( DISCHARGE )
: FERRITE CORE
: TRIAC
: THERMAL FUSE
: TRANSISTOR MODULE
: ELECTRONIC EXPANSION VALVE COIL
: PROTECTIVE EARTH
SiBE05-311
TRM1
+
C14
+
-
C15
+
-
-
W
V
U
OL1
N
W
V
U
1
Z1C
W
V
N
U
M1C
3D038018B
R4T
( FIN )
S91
TRM1
+
C12
C14
+
+
-
-
C13
C15
+
+
-
-
-
W
V
U
OL1
W
V
U
1
Z1C
V
Q1L
W
U
M1C
3D038019C
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents