2.4

Removal of Propeller Fan and Fan Motor

Procedure
Step
Disconnect the fan motor
connector S70.
1
Release the lead-wires
of the fan motor from
the groove of the switch
box.
2
The propeller fan can
be removed when the
washer faced nut (M8)
is removed.
3
Remove two screws for
removing the fan motor.
The lead wires are
disengaged by raising
the hooks which fix the
lead wires.
140
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Washer faced nut
(M8)
Mark
D cut
(R1474)
SiBE05-311
Points
Remove the external plates
and the drip proof cover
protecting the electric parts.
Be sure to avoid forgetting to
restore the shelter and to
avoid loosing or damaging it.
Mark
(R1475)
When restoring, match the
mark of the propeller fan with
the D-cut of the motor shaft.
The fan should be restored
so that the mark
will be at
upper part of the fan motor.