Inspections
1 Select a test area that is firm, level and free of
obstruction.
2 Be sure the battery pack is connected.
At the Ground Controls
3 Pull out the platform and ground red Emergency
Stop buttons to the on position.
4 Turn the key switch to ground control.
5 Observe the diagnostic LED readout on the
platform controls.
Result: The LED should look
like the picture at right.
Test Emergency Stop
6 Push in the ground red Emergency Stop button
to the off position.
Result: No functions should operate.
7 Pull out the red Emergency Stop button to
the on position.
Test the Up/Down Functions
The audible warnings on this machine and the
standard horn all come from the same central
alarm. The horn is a constant tone. The descent
alarm sounds at 60 beeps per minute. The alarm
that goes off when the pothole guards have not
deployed sounds at 300 beeps per minute. The
alarm that goes off when the machine is not level
sounds at 600 beeps per minute. An optional
automotive-style horn is also available.
26
8 Activate the up function.
Result: The platform should raise.
9 Activate the down function.
Result: The platform should lower. The descent
alarm should sound while the platform is
lowering.
Test Emergency Lowering
10 Activate the up function and raise the platform
approximately 60 cm.
11 Pull the Emergency lowering knob located
behind the entry ladder.
Result: The platform should lower. The descent
alarm will not sound.
12 Turn the key switch to platform control.
At the Platform Controls
Test Emergency Stop
13 Push in the platform red Emergency Stop
button to the off position.
Result: No functions should operate.
Test the Horn
14 Pull out the red Emergency Stop button to the
on position.
15 Push the horn button.
Result: The horn should sound.