3.7.4 Tone Settings
Value Range
Default Value
Configuration File Reference
3.7.4.2 Busy Tone
Tone Frequencies
Description
Value Range
Default Value
Configuration File Reference
Tone Timings
Description
Value Range
Default Value
Configuration File Reference
3.7.4.3 Ringing Tone
Tone Frequencies
Description
Value Range
Default Value
Configuration File Reference
116
Administrator Guide
0–5000 (0: Infinite time)
Note
•
The unit will play the tone for the duration of the first value, stop
it for the duration of the second value, play it for the duration of
the third value, and then stop it for the duration of the last value.
The whole sequence will then repeat. For example, if the value
for this setting is "100,100,0,0", the unit will play the tone for 100
ms, stop it for 100 ms, and then play it continuously.
0,0,0,0 (The unit plays the dial tone continuously.)
DIAL_TONE_TIMING (Page 168)
Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
0, 200–1000 (0: No tone)
480,620
BUSY_TONE_FRQ (Page 169)
Specifies the pattern, in milliseconds, of busy tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
0–5000 (0: Infinite time)
500,500,500,500
BUSY_TONE_TIMING (Page 169)
Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
0, 200–1000 (0: No tone)
440,480
RINGING_TONE_FRQ (Page 169)
Document Version
2011-01