Optional Wall Thermostat; Wiring; Final Check; Standard Wiring - Regency I35-NG Owners & Installation

Gas inbuilt
Table of Contents

Advertisement

OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 240V wires.
This heater does not require a 240V A.C. supply
for the gas control to operate. A 240V A.C. power
supply is needed for the fan/blower operation.
Regency I35 Gas Inbuilt Fireplace
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
15.24
16 GA.
9.75
18 GA.
6.10
20 GA.
3.66
22 GA.
2.71

WIRING

Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.

STANDARD WIRING

INSTALLATION

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15
m
minutes.
m
2) If required, adjusting the primary air to
m
ensure that the fl ame does not carbon.
m
First allow the unit to burn for 15 min. to
m
stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of the
manufacturer.
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
NOTE: Switch must be
in "OFF" position to
operate remote.
19