2.7.1 Overview

2.7 Connection of DECT Portable Stations

2.7.1 Overview
Required Equipment and Maximum Number of Calls
CSs determine the area covered by the wireless system. The number of calls that can be made simultaneously
through each CS varies depending on the model, as follows:
CS
KX-TDA0158CE
KX-TDA0141CE
Notice
The CSs for DECT are for connection to specified Panasonic PBXs only.
Note
For more details about the PS, refer to the Operating Instructions of the PS.
Required Distances between Equipment
CAUTION
Maintain the distances listed below between equipment in order to prevent noise, interference or the
disconnection of a conversation. (The distance may vary depending on the environment.)
Equipment
CS and office equipment such as a computer, telex, fax
machine, etc., or microwaves
CS and PS
Each PS
PBX and CS
Too many CSs in a small area can cause problems due to conflicts over which signal channels each
CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the environment of the
installation site and conditions in which the wireless system is used. Conduct the site survey to
determine the appropriate distance.
RF Specification
Radio Access Method
122
Installation Manual
Connection Port/Card
Super Hybrid Port/DLC card
Super Hybrid Port/DLC card
Item
Maximum Calls
8
2
Distance
More than 2 m
More than 1 m
More than 0.5 m
More than 2 m
MultiCarrier TDMA-TDD
Compatible PSs
KX-TCA155
KX-TCA255
KX-TCA256
KX-TCA355
KX-TD7590
KX-TD7580
Description