Connection Of Dect Portable Stations; Overview - Panasonic KX-TDE100 Installation Manual

Pure ip-pbx
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

3.9 Connection of DECT Portable Stations

3.9.1 Overview

Required Equipment and Maximum Number of Calls
CSs determine the area covered by the wireless system. The number of calls that can be made simultaneously
through each CS varies depending on the model, as follows:
CS
KX-TDA0158CE
KX-TDA0141CE
KX-TDA0142CE
Notice
The CSs for DECT are for connection to specified Panasonic PBXs only.
Note
For more details about the PS, refer to the Operating Instructions of the PS.
Required Distances between Equipment
CAUTION
Maintain the distances listed below between equipment in order to prevent noise, interference or the
disconnection of a conversation. (The distance may vary depending on the environment.)
Equipment
CS and office equipment such as a computer, telex, fax
machine, etc., or microwaves
CS and PS
Each PS
PBX and CS
Notice
Too many CSs in a small area can cause problems due to conflicts over which signal channels each CS
can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the environment of the installation
site and conditions in which the wireless system is used. Conduct the site survey to determine the
appropriate distance.
RF Specification
Radio Access Method
Connection Card
DHLC/DLC
DHLC/DLC
CSIF
Item
Maximum Calls
8
2
4
Distance
More than 2 m
More than 1 m
More than 0.5 m
More than 2 m
MultiCarrier TDMA-TDD
Compatible PSs
KX-TCA155
KX-TCA255
KX-TCA256
KX-TCA355
KX-TD7590
KX-TD7580
Description
Installation Manual
3.9.1 Overview
159

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pure ip-pbxKx-tde200Tde100Tde200

Table of Contents