Specifications; Standard Series - Mitsubishi FREQROL-U100 Instruction Manual

General purpose inverter
Table of Contents

Advertisement

7. SPECIFICATIONS
• Standard series
Model
FR-U120-C]-(C). -CULl
O.1K
0.2K
0.4K
a.75K
1.5K
Applicable motor capacity (kW)/(HP) *1
0.1/1/8
0.2/1/4
0.4/1/2
0.75/1
1.5/2
Rated capacity (kVA)
*'
0.3
0.5
0.9
1.5
2.6
Rated output current (A)
0.8
1.4
2.4
4.1
7
Output
Overload current rating
*3
150% 60
sec.
200% 0.5
sec. (inverse time
characteristic)
Rated output voltage
*4
a-pheee 200 to 230V
(The 1.5k model of the fully enclosed type is 200 to 220V.)
a-phase 200 to 230V, SO/60Hz
Rated input AC voltage
(The 1.5k model of the fully enclosed type is a-phase
200V 50Hz, 3-phase 200 to 220V 60Hz. )
Power
180 to 253V. SO/60Hz
supply
Tolerable AC voltage fluctuation
(The 1.5k model of the fully enclosed type is 180 to
220V 50Hz, 180 to 242V 60Hz. )
Tolerable frequency fluctuation
±5%
Power supply capacity O:VA)
*
5
0.4
0.7
I
1.2
2.1
4.0
Enclosure
Enclosed type
(I
P20) Fully enclosed type is IP40.)
Cooling method
Self-cooling (Without cooling fan)
(The 1.5k model of the fully enclosed type is force-cooled.)
Weight (kg)
0.5 *7
0.6 *7
0.7 * 7
I
0.9 *7
1.7 *7
-46-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents