Single Phase 20Dv Input Series - Mitsubishi FREQROL-U100 Instruction Manual

General purpose inverter
Table of Contents

Advertisement

• Single phase 200V input series
I
Standard series FR U120S
0
(UL)
O.lK
O.2K
OAK
O.75K
Model
Low-acoustic
no~s~ie~
(I 1 )
O.1K
O.2K
OAK
0.75K
FR-U120S-N
-
UL
Applicable motor capacity
(kW)/(HP)
* 1
0.1/1/8
0.2/1/4
0.4/1/2
0.75/1
Rated capacity (kVA)
*2
0.3
0.5
0.9
1.5
Rated output current (A)
0.8
1.4
2.4
4.1
Output
Overload current rating
*3
150% 60 sec. 200%
u.s
sec. (inverse time characteristic)
Rated output voltage
*4
s-pnese 200 to 220V (The model of UL type is 200 to 230V)
Rated input AC voltage
Single ohese 200V 50Hz. 200 to zarv 60Hz (UL type
~
200 to 230V, 50/60Hz)
Power
Tolerable AC voltage fluctuation
180to 220VSOHz, 180to 242V 60Hz (UL type is 180to 253V, 50/60Hz)
supply
Tolerable frequency fluctuation
5%
Power supply capacity
(kVA)
*5
0.5
I
0.9
I
1.5
I
2.5
Enclosure
Enclosed type (I P20)
Cooling method
Self-cooling (without cooling fan)
Weight (kg)
0.6
I
0.7
I
0.9
I
1.7
(Note)
*
1. The maximum applicable capacity is for the Mitsubishi standard motor 4p, This may not apply to the 6P motor.
so refer to the rated output current.
*2. The rated capacity is shown for the output voltage of 220V (60Hz).
*3. The overload current value % shows the ratio to the inverter's rated output current.
*4. The output voltage cannot exceed the power supply voltage.
*5. The necessary power capacity will differ according to the impedanceon the power supply side (including reactor and
power wires on input side). Prepare a power supply capacity higher than the noted value.
*6. If a load is applied on the motor. the output voltage will drop approx. \0 to 15%. so the load must be reduced
when using a general purpose motor.
*
7. The lcw-ecoustio noise. fully enclosed type wl11 be O.lkg heavier.