4. Troubleshooting
Diagnostics > Adjustment > Scan Area Adjustment > Manual Adjustment
Purpose
Operation Procedure
Verification
Specification
Reference
4-59
To correct image position and magnification of scanned images manually. This function is used when
a result of automatic adjustment does not satisfy the expectation.
1) Choose one item from the table. There are three items to choose.
Image Position - Leading Edge
Image Position - Side Edge
Magnification - Vertical Direction
2) Select one item and press the "Edit" button.
3) Change the adjustment value with arrow button.
4) Image Position (a, b) : If the current value is smaller than the specification, press "+".
Otherwise, press "-".
5) Magnification (c) : If the current value is smaller than the specification, press "-". Otherwise,
press "+".
6) Press the "OK" button to apply the new value to the system.
NOTE
The value of magnification adjustment needs to be calculated based on A3 size, 420mm ((190mm +
10mm*2)*2) if the used Scanner A/S Chart is A4 size.
1) Scan the Scanner A/S Chart and send it to a PC. Scanning must be occur from the scan glass.
2) To check the image position, compare the position of scale marks (a,b) of the chart to the
copy.
3) To check the magnification, compare the length of line "c" of the chart to the copy .
a,b : 10 , ± 1.5 mm
c: 190 , ± 1.5 mm
Image Position Unit : mm, Scale : 0.1, Min/Max : -6/+6
Magnification Unit : %, Scale: 0.1(0.42mm), Min/Max: 99/101
A4 Scanner A/S Chart