4.2 Parameter List

4.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial value of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel (FR-DU07).
REMARKS
indicates simple mode parameters. (initially set to extended mode)
The shaded parameters in the table allow its setting to be changed during operation even if "0" (initial value) is set in Pr. 77 Parameter write
selection.
Refer to Appendix 2 (page 466) for instruction codes for communication and availability of parameter clear, all clear, and parameter copy of
each parameter.
Parameters with
have different specifications according to the date assembled. Refer to page
Func-
Parameter
tion
Torque boost
0
1
Maximum frequency
Minimum frequency
2
Base frequency
3
Multi-speed setting (high speed)
4
5
Multi-speed setting (middle speed)
Multi-speed setting (low speed)
6
Acceleration time
7
8
Deceleration time
Electronic thermal O/L relay
9
10
DC injection brake operation frequency 0 to 120Hz, 9999
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
Stall prevention operation level
22
(torque limit level )
Stall prevention operation level
23
compensation factor at double speed
24 to 27
Multi-speed setting(4 speed to 7 speed)
28
Multi-speed input compensation selection
Acceleration/deceleration pattern
29
selection
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
Name
Setting Range
0 to 30%
0 to 120Hz
0 to 120Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600/360s
0 to 3600/360s
0 to 500/0 to 3600A
0 to 10s, 8888
0 to 30%
0 to 60Hz
0 to 5
0 to 400Hz
0 to 3600/360s
0, 2, 4
120 to 400Hz
0 to 1000V, 8888, 9999
1 to 400Hz
0, 1
0 to 400%
0 to 200%, 9999
0 to 400Hz, 9999
0, 1
0 to 5
0, 1, 2, 10, 11, 20, 21
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 1 to 9998
484
to check the SERIAL number.
Minimum
Setting
Initial Value
Increments
/1
0.1%
6/4/3/2
%
/60
0.01Hz
120
Hz
0.01Hz
0Hz
0.01Hz
60Hz
0.01Hz
60Hz
0.01Hz
30Hz
0.01Hz
10Hz
0.1/0.01s
5/15s
*3
0.1/0.01s
5/15s
*3
Rated inverter
/0.1
0.01
A
*2
*2
current
0.01Hz
3Hz
0.1s
0.5s
0.1%
4/2
/1
%
0.01Hz
0.5Hz
1
0
0.01Hz
5Hz
0.1/0.01s
0.5s
1
0
/60
0.01Hz
120
Hz
0.1V
9999
0.01Hz
60Hz
1
0
0.1%
150%
0.1%
9999
0.01Hz
9999
1
0
1
0
1
0
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
Parameter List
Refer
Customer
to
Setting
Page
146
*1
157
*2
157
159
165
165
165
172
172
183
203
203
203
*4
175
161
167
167
234
157
*2
159
172
172
100,
4
152
152
165
169
176
207
158
158
158
158
158
158
251
71