Parameter List
Func-
Parameter
tion
Digital position control sudden stop
464
*6
deceleration time
465
First position feed amount lower 4 digits
*6
466
First position feed amount upper 4 digits
*6
467
Second position feed amount lower 4 digits 0 to 9999
*6
468
Second position feed amount upper 4 digits 0 to 9999
*6
469
Third position feed amount lower 4 digits
*6
470
Third position feed amount upper 4 digits
*6
471
Fourth position feed amount lower 4 digits
*6
472
Fourth position feed amount upper 4 digits
*6
473
Fifth position feed amount lower 4 digits
*6
474
Fifth position feed amount upper 4 digits
*6
475
Sixth position feed amount lower 4 digits
*6
476
Sixth position feed amount upper 4 digits
*6
477
Seventh position feed amount lower 4 digits
*6
478
Seventh position feed amount upper 4 digits
*6
479
Eighth position feed amount lower 4 digits
*6
480
Eighth position feed amount upper 4 digits
*6
481
Ninth position feed amount lower 4 digits
*6
482
Ninth position feed amount upper 4 digits
*6
483
Tenth position feed amount lower 4 digits
*6
484
Tenth position feed amount upper 4 digits
*6
485
Eleventh position feed amount lower 4 digits
*6
486
Eleventh position feed amount upper 4 digits
*6
487
Twelfth position feed amount lower 4 digits
*6
488
Twelfth position feed amount upper 4 digits
*6
489
Thirteenth position feed amount lower 4 digits 0 to 9999
*6
490
Thirteenth position feed amount upper 4 digits 0 to 9999
*6
491
Fourteenth position feed amount lower 4 digits
*6
492
Fourteenth position feed amount upper 4 digits 0 to 9999
*6
493
Fifteenth position feed amount lower 4 digits
*6
494
Fifteenth position feed amount upper 4 digits
*6
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
Maintenance timer alarm output set
504
time
505
Speed setting reference
516
S-pattern time at a start of acceleration
S-pattern time at a completion of
517
acceleration
518
S-pattern time at a start of deceleration
S-pattern time at a completion of
519
deceleration
Modbus-RTU communication check
539
time interval
547
USB communication station number
USB communication check time
548
interval
549
Protocol selection
NET mode operation command source
550
selection
551
PU mode operation command source
selection
80
Name
0 to 360s
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0 to 9999
0, 1, 10, 11
0 to 4095
0 to 4095
0 (1 to 9998)
0 to 9998, 9999
1 to 120Hz
0.1 to 2.5s
0.1 to 2.5s
0.1 to 2.5s
0.1 to 2.5s
0 to 999.8s, 9999
0 to 31
0 to 999.8s, 9999
0, 1
0, 1, 9999
1, 2, 3, 9999
Minimum
Setting Range
Setting
Increments
0.1s
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.01Hz
0.1s
0.1s
0.1s
0.1s
0.1s
1
0.1s
1
1
1
Refer
Customer
Initial Value
to
Setting
Page
0
134
s
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
134
0
250
0
250
0
250
0
389
9999
389
60Hz
251
0.1s
176
0.1s
176
0.1s
176
0.1s
176
9999
347
0
360
9999
360
0
347
9999
322
9999
322