Communication operation and setting
List of calibration parameters
Para
Name
meter
C2
Terminal 2 frequency
(902)
setting bias frequency
C3
Terminal 2 frequency
(902)
setting bias
125
Terminal 2 frequency
(903)
setting gain frequency
C4
Terminal 2 frequency
(903)
setting gain
C5
Terminal 4 frequency
(904)
setting bias frequency
C6
Terminal 4 frequency
(904)
setting bias
126
Terminal 4 frequency
(905)
setting gain frequency
C7
Terminal 4 frequency
(905)
setting gain
C12
Terminal 1 bias
(917)
frequency (speed)
[Special monitor selection No.]
Refer to page 253 for details of the monitor description.
Data
Description
H01 Output frequency/speed
H02 Output current
H03 Output voltage
Frequency setting value/
H05
speed setting
*7
H06 Running speed
H07 Motor torque
H08 Converter output voltage
H09 Regenerative brake duty
Electronic thermal relay
H0A
function load factor
Output current peak
H0B
value
Converter output voltage
H0C
peak value
...........Specifications differ according to the date assembled. Refer to page 484 to check the SERIAL number.
*1
The setting depends on capacities. (55K or lower / 75K or higher)
*2
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
*3
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
*4
Details of option input terminal monitor 1 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0)-all terminals
are OFF when an option is not fitted
b15
X15
X14
X13
*5
Details of option input terminal monitor 2 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
b15
*6
Details of option output terminal monitor (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
b15
*7
When Pr. 37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 251)
344
Instruction
code
Para
meter
C13
Terminal 1 bias
5E DE 1
(917)
frequency (speed)
C14
Terminal 1 gain
5E DE 1
(918)
frequency (speed)
C15
Terminal 1 gain
5F DF 1
(918)
(speed)
Terminal 1 bias
C16
5F DF 1
command (torque/
(919)
magnetic flux)
60 E0
1
C17
Terminal 1 bias
(919)
(torque/magnetic flux)
60 E0
1
Terminal 1 gain
C18
command (torque/
(920)
61 E1
1
magnetic flux)
C19
Terminal 1 gain
61 E1
1
(920)
(torque/magnetic flux)
11 91
9
Increments
Data
Description
0.01Hz/1
*7
H0D Input power
0.01A/
0.1A
*1
H0E Output power
0.1V
H0F Input terminal status
0.01Hz/1
H10 Output terminal status
1r/min
H11 Load meter
0.1%
H12 Motor excitation current
0.1V
H13 Position pulse
0.1%
Cumulative energization
H14
0.1%
time
0.01A/
H16 Orientation status
0.1A
H17 Actual operation time
*1
H18 Motor load factor
0.1V
H19 Cumulative power
H20 Torque command
CS
RES
STOP
X12
X11
X10
X9
RA3
Instruction
code
Name
11 91
9
12 92
9
12 92
9
13 93
9
13 93
9
14 94
9
14 94
9
Increments
0.01kW/
0.1kW
*1
0.01kW/
0.1kW
*1
*2
*3
0.1%
0.01A/
0.1A
*1
1h
1h
0.1%
1kWh
0.1%
MRS
JOG
RH
RM
ABC2 ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Para
Name
meter
Terminal 4 bias
C38
command (torque/
(932)
magnetic flux)
C39
Terminal 4 bias
(932)
(torque/magnetic flux)
Terminal 4 gain
C40
command (torque/
(933)
magnetic flux)
C41
Terminal 4 gain
(933)
(torque/magnetic flux)
Data
Description
H21 Torque current command
H22 Motor output
H23 Feedback pulse
H2E Motor temperature
H32 Power saving effect
H33 Cumulative saving power Variable
H34 PID set point
H35 PID measured value
H36 PID deviation value
Option input terminal
H3A
status1
*4
Option input terminal
H3B
status2
*5
Option output terminal
H3C
status
*6
RL
RT
AU
FU
OL
IPF
X4
X3
X2
Y4
Y3
Y2
Instruction
code
20 A0
9
20 A0
9
21 A1
9
21 A1
9
Increments
0.1%
0.01kW/
0.1kW
*1
1°C
Variable
0.1%
0.1%
0.1%
b0
STR
STF
b0
SU
RUN
b0
X1
X0
b0
DY
b0
Y1
Y0

Hide quick links: