1.4
Applied motor (Pr. 71)
Setting of the used motor selects the thermal characteristic appropriate for the motor.
Setting is necessary when using a constant-torque motor. Thermal characteristic of the electronic
thermal relay function suitable for the motor is set.
When PM sensorless vector control is selected, the motor constants (MM-CF etc.) necessary for control
are selected as well.
Parameter
Number
71
Applied motor
(1) Set the motor to be used
Refer to the following list and set this parameter according to the motor used.
Pr. 71 Setting
330
IPM Motor MM-CF
*
333
IPM Motor MM-CF
*
8093
IPM Motor (other than MM-CF)
334
IPM Motor MM-CF
*
8094
IPM Motor (other than MM-CF)
* The setting is available for FR-A720-11K or lower.
REMARKS
 When performing offline auto tuning, set "3, 7, 8, 13, 17, 18, 23, 33, 43, 53, 333, 8093" in Pr. 71.
(Refer to page 7 for offline auto tuning)
 For the 5.5K and 7.5K, the Pr. 0 Torque boost and Pr. 12 DC injection brake operation voltage settings are automatically
changed according to the Pr. 71 setting as follows.
Pr.71
0, 2, 3 to 8, 20, 23, 24, 40, 43, 44,
330, 333, 334, 8093, 8094
Pr. 0
Pr. 12
Initial
Name
Value
0
Standard Motor Setting
3%
4%
Setting Range
0 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 330, 333,
334, 8093, 8094
Motor
Select "offline auto tuning setting"
Auto tuning data can be read,
changed, and set
Constant Torque
Motor Setting
1, 13 to 18, 50, 53, 54
2%
2%
12/24
Description
Selecting the standard motor or constant-
torque motor sets the corresponding
motor thermal characteristic.
Electronic thermal relay
function operation
characteristic
Constant
torque
BCN-C22005-634
IPM

Hide quick links: