Mitsubishi Electric FR-A720-0.4K Instruction Manual page 468

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type with brake)
Frame Number 90L
SF-V5RUF(H)
1KB
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
LL
KB
Exhaust
Main
terminal box
Suction
Section
1
2
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 160M, 160L
SF-V5RUF(H)
11KB
,
15KB
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Flange
Frame
F KB
F K1B
F K3B
F K4B
Number
No.
1
FF165
90L
2
1
FF215 100L
3
2
1
FF215 112M
5
3
2
FF265 132S
7
5
3
1
FF265 132M
11
7
5
2
FF300 160M
15
11
7
3
FF300 160L
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
LR
LG
LE
KL
Q
QK
LN LZ
AA
1
B
A
B
A
2
W
S
Main terminal box
For brake (B1, B2)
Section BB
For motor (U, V, W)
For thermal protector (G1, G2)
B1
B2
U
V
W
G1 G2
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
LL
Exhaust
Suction
1, 2
Direction of
cooling fan wind
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Main terminal box
For motor (U, V, W)
Earthing
U
V
W
(grounding)
terminal (M8)
B1
B2
G1
G2
For brake (B1, B2)
For thermal protector (G1, G2)
Mass
(kg)
D
KB
KD
KL
KP
LA
31.5
183.6 198.5
27
220
155
165
50
207
213
27
231
165
215
58
228
239
27
242
178
215
83
266
256
27
256
197
265
88
266
294
27
256
197
265
151
318
318
56
330
231
300
167
318
362
56
330
231
300
0
-0.5
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H)
2KB
,
3KB
Connector (for encoder)
Terminal box for cooling fan
MS3102A20-29P
LL
Exhaust
Suction
1
2
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Terminal box for cooling fan
For cooling fan (A, B)
A
B
C
Earthing
Earthing
(grounding)
(grounding)
terminal (M4)
terminal (M4)
KB
LR
KL
LG
LE
Main
Q
terminal box
1
QK
Section
AA
A
B
B
A
Terminal box for cooling fan
For cooling fan (A, B, C)
A
B
C
indicates an inserting position of a bolt with hex head holes
Earthing
(grounding)
for manual opening.
terminal (M4)
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Motor
LB
LC
LE
LG
LL
LN
LZ
130j6
200
3.5
12
442
4
12
180j6
250
4
16
481.5
4
14.5
180j6
250
4
16
525
4
14.5
230j6
300
4
20
597
4
14.5
230j6
300
4
20
635
4
14.5
250j6
350
5
20
735.5
4
18.5
110
250j6
350
5
20
779.5
4
18.5
110
Outline dimension drawings
,
5KB
,
7KB
LR
KB
Q
KL
LG
LE
Main
1
QK
terminal box
Section
A
AA
B
B
A
W
S
Section BB
LN
LZ
2
W
S
Section BB
Shaft End
Terminal Screw Size
LR
Q
QK
S
T
U
W
U,V,W A,B,(C) B1,B2 G1,G2
50
50
40
24j6
7
4
8
M6
60
60
45
28j6
7
4
8
M6
60
60
45
28j6
7
4
8
M6
80
80
63
38k6
8
5
10
M6
80
80
63
38k6
8
5
10
M6
110
90
42k6
8
5
12
M8
110
90
42k6
8
5
12
M8
LN
LZ
2
(Unit: mm)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
7
457

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents