MAP 152d: 1.5 V Auxiliary Current/Voltage Problem in Processor
Subsystem
Step 152d-1
Record the error code and the location code(s) that sent you to this MAP.
Step 152d-2
Turn off the power.
Examine the amber logic-power LEDs of all installed processor subsystem DCAs.
Step 152d-3
Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
Yes
Go to "Step 152d-4".
No
Call for support.
Step 152d-4
Pull out the following books about 25 mm (1 inch), if present:
v Memory book 0, at location U1.18-P1-M2
v Memory book 1, at location U1.18-P1-M3
v Memory book 2, at location U1.18-P1-M7
v Memory book 3, at location U1.18-P1-M6
Step 152d-5
Turn on the power.
Step 152d-6
Did the system stop with the same error code as recorded in "Step 152d-1"?
Yes
Go to "Step 152d-12" on page 181.
No
Go to "Step 152d-7".
Step 152d-7
One of the books just removed is defective.
Turn off the power.
Make sure all amber logic-power LEDs of all installed processor subsystem DCAs are off.
180
Eserver pSeries 670 Service Guide