MAP 1549: Attention Problem Isolation

Step 1549-1
Record the error code and the location code(s) that sent you to this MAP.
Step 1549-2
Turn off the power.
Examine the amber logic-power LEDs of all installed processor subsystem DCAs.
Step 1549-3
Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
No
Call for support.
Yes
Go to "Step 1549-4".
Step 1549-4
Examine the following table and locate the error code that sent you to this MAP to determine your next
step.
Error Code
406x 0EB1
406x 0EB2
406x 0EB3
406x 0EB4
406x 0EB5
406x 0EB6
406x 0EB7
406x 0EB8
406x 0EB9
406x 0EBA
406x 0EBB
406x 0EBC
Action
Go to "Step 1549-5" on page 294.
Go to "Step 1549-9" on page 295.
Go to "Step 1549-13" on page 296.
Go to "Step 1549-33" on page 299.
Go to "Step 1549-29" on page 298.
Go to "Step 1549-33" on page 299.
Go to "Step 1549-33" on page 299.
Go to "Step 1549-33" on page 299.
Go to "Step 1549-33" on page 299.
Go to "Step 1549-17" on page 296.
Go to "Step 1549-21" on page 297.
Go to "Step 1549-25" on page 298.
Chapter 3. Maintenance Analysis Procedures