LCD Progress Indicator Log

The following is an example of the LCD progress indicator log. It shows the types of entries that may
appear in the log, and is for example purposes only.
The progress indicator codes are listed from top (latest) to bottom (oldest).
LCD Progress Indicator Log
B0FF
0539..17
0538..17
0539..17
0538..17
0539..17
0581
0538..17
0539..12
0538..12
0539..
0821..01-K1-00
0539..
0728..01-R1-00-00
0539..
0664..40-60-00-1,0
0539..
0777..U1.5-P1-I14/E1
0539..
0742..U1.5-P1-I12/E1
0539..
0776..U1.5-P1-I10/T1
E139
E1FB
E139
E183
Press Return to continue, or 'x' to return to menu. >
EAA1..U1.9-P1-I14
E172..U1.9-P1
E172..U1.9-P1-I14
E172..U1.9-P1
94BB
9109
9380
9108
9107
9106
9105
9118
9104
9103
9102
90FD

Resetting the Service Processor

Some error conditions might cause the service processor to hang. The service processor must be reset to
recover from a hung condition. If the system is powered on, resetting the service processor will cause the
system to shut down. When the service processor is reset, it carries out its power-on sequence, including
self-tests. Successful completion of the reset sequence is indicated by OK in the operator panel in the
media drawer.
Before resetting the service processor, if the managed system is powered on and running, shut down all
partitions, or the full system partition. This action causes the system to shut down and the system power is
turned off.
To reset the service processor when the managed system is powered off, perform either of the following:
758