3.4 [1-1] Slot—Card Property - IPCMPR (for KX-NCP500/KX-NCP1000/KX-TDE100/KX-TDE200)/IPCEMPR (for
KX-TDE600)
CNG Signal Fixation Detection Counter
Specifies the number of times the CNG signal must be detected before the PBX proceeds the fax operation.
Default
1
Value Range
1–3
Maintenance Console Location
3.4 [1-1] Slot—Card Property - IPCMPR (for KX-NCP500/KX-NCP1000/KX-TDE100/KX-TDE200)/IPCEMPR
(for KX-TDE600)
Programming Manual References
None
Feature Manual References
None
CED Signal Fixation Detection Time
Specifies the minimum length of time required for the CED (called station identification) signal to be detected
by the PBX.
Default
100 ms
Value Range
50 ´ n (n=1–100) ms
Maintenance Console Location
3.4 [1-1] Slot—Card Property - IPCMPR (for KX-NCP500/KX-NCP1000/KX-TDE100/KX-TDE200)/IPCEMPR
(for KX-TDE600)
Programming Manual References
None
Feature Manual References
None
T38 FAX Transmit Level (Network to PBX) A-Law
Specifies the transmission level of G3 fax signals after being converted from T.38 protocol packets, when the
codec used is G.711A.