11. Soft Switch List
MODE
Bit:
418
Bit
Feature
6
Document erase width.
5
4
Stop when the lifetime of
imaging unit ends.
3
Display a message when
the status of the imaging
unit is "near life".
132
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 1
1 0 0 0
Logic
0
1
Bit 6-5:
00
01
10
11
Stop
Do not
stop
Do not
Display
display
Field Service Ver. 1.0 Aug. 2005
HEX:58
Description
0 mm
1 mm
2 mm
3 mm
Specify operation (stop or not stop)
when the lifetime of imaging unit ends.
Specify operation (display or not display)
when the status of the imaging unit is
"near life".