Thermistor

1. Remove the Fusing Unit.
37
[1]
[2]
[3]
[5]
[8]
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
2. Snap off the C-clip [1] and remove
the Fusing Entrance Guide Plate [2].
4040F2C625DA
3. Remove two shoulder screws [3], the
screw [4], and the Exit Rolls 2 Assy
[4]
[5].
[3]
4040F2C643DA
4. Remove the wiring saddle [6] and
the harness.
[6]
4040F2C730DA
5. Disconnect the connector [7] of the
Exit Sensor and remove the Exit
Rolls 2 Assy [8].
[7]
4040F2C431DA