4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > Procedure
Removing the Main Controller PCB
■ Before Replacing the Main Controller PCB
• Check the version.
Service mode > COPIER > DISPLAY > VERSION
• Output the system data on a piece of paper as needed.
Service mode> COPIER > FUNCTION > MISC-P > OUTPUT >SYS-DAT
• Export address book data to the PC (backup of address book data)
■ Preparation
1) Remove the Left Cover (Refer to page 4-27).
■ Procedure
NOTE:
Between L100/L170/L174/L250/L150 CHN/L150 KOR/L154 model and L150 EUR/L150
AUS model, the number of connectors to be disconnected differs.
•
For L100/L170/L174/L250/L150 CHN/L150 KOR/L154 model, refer to step 1-1.
•
For L150 EUR/L150 AUS model, refer to step 1-2.
4
Disassembly/Assembly > Controller System > Removing the Main Controller PCB > Procedure
<For L100/L170/L174/L250/L150 CHN/L150 KOR/L154 model>
1-1) Disconnect the 3 Flat Cables [1] and the 6 connectors [2].
[1]
x9
[1]
<For L150 EUR/L150 AUS model>
1-2) Disconnect the 3 Flat Cables [1] and the 5 connectors [2].
[1]
x8
[1]
4-39
[2]
[2]
[1]
[2]
F-4-61
[2]
[2]
[1]
[2]
F-4-62
4-39